Skip to content

Latest commit

 

History

History
53 lines (40 loc) · 2.1 KB

iron_and_manganese_removal_zo.rst

File metadata and controls

53 lines (40 loc) · 2.1 KB

Iron And Manganese Removal (ZO)

Model Type

This unit model is formulated as a single-input, double-output model form. See documentation for :ref:`single-input, double-output Helper Methods<sido_methods>`.

Electricity Consumption

The constraint used to calculate energy consumption is described in the Additional Constraints section below. More details can be found in the unit model class.

Costing Method

Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.iron_and_manganese_removal_zo.IronManganeseRemovalZOData.cost_iron_and_manganese_removal` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.

Additional Variables

Description Variable Name Units
Ratio of air to water air_water_ratio dimensionless
Flow basis flow_basis m^3/h
Air flow rate air_flow_rate m^3/h
Constant in electricity intensity equation electricity_intensity_parameter h*hp/m^3
Dual media filter surface area filter_surf_area m^2
Number of dual media filter units num_filter_units dimensionless
Power consumption of iron and manganese removal electricity kW
Specific energy consumption with respect to feed flowrate electricity_intensity kWh/m^3

Additional Constraints

Description Constraint Name
Air flow rate constraint air_flow_rate_constraint
Electricity intensity constraint electricity_intensity_constraint
Power consumption constraint electricity_constraint
.. index::
   pair: watertap.unit_models.zero_order.iron_and_manganese_removal_zo;iron_and_manganese_removal_zo

.. currentmodule:: watertap.unit_models.zero_order.iron_and_manganese_removal_zo

Class Documentation

.. automodule:: watertap.unit_models.zero_order.iron_and_manganese_removal_zo
    :members: