This unit model is formulated as a reactive single-inlet, double-outlet model form. See documentation for :ref:`reactive single-inlet, double-outlet Helper Methods<sidor_methods>`.
Electricity consumption is calculated using the constant_intensity helper function. See documentation for :ref:`Helper Methods for Electricity Demand<electricity_methods>`.
Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.mabr_zo.MABRZOData.cost_mabr` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.
Description | Variable Name | Units |
---|---|---|
Nitrogen removal rate per day | nitrogen_removal_rate | g/d/m^2 |
Sizing variable for effective reactor area | reactor_area | m^2 |
Air flow rate per area | air_flow_rate | m/h |
Volumetric air flow rate | air_flow_vol | m^3/h |
Description | Constraint Name |
---|---|
Constraint for effective reactor area | reactor_area_constraint |
Constraint for air flow | air_flow_constraint |
.. index:: pair: watertap.unit_models.zero_order.mabr_zo;mabr_zo
.. currentmodule:: watertap.unit_models.zero_order.mabr_zo
.. automodule:: watertap.unit_models.zero_order.mabr_zo :members: :noindex: