Model Type

This unit model is formulated as a single-input, double-output model form. See documentation for :ref:`single-input, double-output Helper Methods<sido_methods>`.

Electricity Consumption

Electricity consumption is calculated using the constant_intensity helper function. See documentation for :ref:`Helper Methods for Electricity Demand<electricity_methods>`.

Costing Method

Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.membrane_evaporator_zo.MembraneEvaporatorData.cost_membrane_evaporator` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.

Additional Variables

Description Variable Name Units
Water flux through membrane water_flux m/h
Membrane area membrane_area m^2

Additional Constraints

Description Constraint Name
Constraint for water flux. wat_flux
.. index::
   pair: watertap.unit_models.zero_order.membrane_evaporator_zo;membrane_evaporator_zo

.. currentmodule:: watertap.unit_models.zero_order.membrane_evaporator_zo

Class Documentation

.. automodule:: watertap.unit_models.zero_order.membrane_evaporator_zo
    :members: