Skip to content

Latest commit

 

History

History
46 lines (33 loc) · 1.4 KB

File metadata and controls

46 lines (33 loc) · 1.4 KB

Sedimentation (ZO)

Model Type

This unit model is formulated as a single-input, double-output model form. See documentation for :ref:`single-input, double-output Helper Methods<sido_methods>`.

Electricity Consumption

Electricity consumption is calculated using the constant_intensity helper function. See documentation for :ref:`Helper Methods for Electricity Demand<electricity_methods>`.

Costing Method

Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.sedimentation_zo.SedimentationZOData.cost_sedimentation` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.

Additional Variables

Description Variable Name Units
Surface area of sedimentation tank basin_surface_area ft^2
Particle settling velocity settling_velocity m/s

Additional Constraints

Description Constraint Name
None basin_surface_area_constraint
.. index::
   pair: watertap.unit_models.zero_order.sedimentation_zo;sedimentation_zo

.. currentmodule:: watertap.unit_models.zero_order.sedimentation_zo

Class Documentation

.. automodule:: watertap.unit_models.zero_order.sedimentation_zo
    :members: