This unit model is formulated as a pass-through model form. See documentation for :ref:`pass-through Helper Methods<pt_methods>`.
The constraint used to calculate energy consumption is described in the Additional Constraints section below. More details can be found in the unit model class.
Costing is calculated using the :py:meth:`~watertap.core.zero_order_base.ZeroOrderBaseData.cost_power_law_flow` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.
Description | Variable Name | Units |
---|---|---|
Electricity consumption of unit | electricity | kW |
Lift height for pump | lift_height | ft |
Efficiency of pump | eta_pump | dimensionless |
Efficiency of motor | eta_motor | dimensionless |
Description | Constraint Name |
---|---|
Constraint for electricity consumption based on pump flowrate. | electricity_consumption |
.. index:: pair: watertap.unit_models.zero_order.water_pumping_station_zo;water_pumping_station_zo
.. currentmodule:: watertap.unit_models.zero_order.water_pumping_station_zo
.. automodule:: watertap.unit_models.zero_order.water_pumping_station_zo :members: :noindex: