This unit model is formulated as a pass-through model form. See documentation for :ref:`pass-through Helper Methods<pt_methods>`.
The constraint used to calculate energy consumption is described in the Additional Constraints section below. More details can be found in the unit model class.
Costing is calculated using the :py:meth:`~watertap.unit_models.zero_order.chemical_addition_zo.ChemicalAdditionZOData.cost_chemical_addition` method. For full details on costing, see documentation for the :ref:`zero-order costing package<zero_order_costing>`.
Description | Variable Name | Units |
---|---|---|
Dosing rate of chemical | chemical_dosage | mg/l |
Mass density of chemical solution | solution_density | kg/m^3 |
Mass fraction of chemical in solution | ratio_in_solution | dimensionless |
Volumetric flow rate of chemical solution | chemical_flow_vol | m^3/s |
Electricity consumption of unit | electricity | kW |
Description | Constraint Name |
---|---|
None | chemical_flow_constraint |
Constraint for electricity consumption based on pump flowrate. | electricity_consumption |
.. index:: pair: watertap.unit_models.zero_order.chemical_addition_zo;chemical_addition_zo
.. currentmodule:: watertap.unit_models.zero_order.chemical_addition_zo
.. automodule:: watertap.unit_models.zero_order.chemical_addition_zo :members: :noindex: