This unit model is formulated as a single-input, double-output model form. See documentation for single-input, double-output Helper Methods<sido_methods>
.
Electricity consumption is calculated using the constant_intensity helper function. See documentation for Helper Methods for Electricity Demand<electricity_methods>
.
Costing is calculated using the cost_centrifuge method in the zero-order costing package. See documentation for the zero-order costing package<zero_order_costing>
.
Description | Variable Name | Units |
---|---|---|
Dosing rate of polymer | polymer_dose | mg/l |
Consumption rate of polymer | polymer_demand | kg/h |
Description | Constraint Name |
---|---|
Polymer demand constraint | polymer_demand_equation |
pair: watertap.unit_models.zero_order.centrifuge_zo;centrifuge_zo
watertap.unit_models.zero_order.centrifuge_zo
watertap.unit_models.zero_order.centrifuge_zo