This unit model is formulated as a single-input, single-output model form. See documentation for :ref:`single-input, single-output Helper Methods<siso_methods>`.
The constraint used to calculate energy consumption is described in the Additional Constraints section below. More details can be found in the unit model class.
Costing is calculated using the cost_ozonation_aop method in the zero-order costing package. See documentation for the :ref:`zero-order costing package<zero_order_costing>`.
Description | Variable Name | Units |
---|---|---|
Ozone contact time | contact_time | min |
CT value for ozone contactor | concentration_time | mg*min/l |
Ozone mass transfer efficiency | mass_transfer_efficiency | dimensionless |
Specific energy consumption for ozone generation | specific_energy_coeff | kWh/lb |
Mass flow rate of ozone | ozone_flow_mass | lb/h |
Ozone consumption | ozone_consumption | mg/l |
Ozone generation power demand | electricity | kW |
Oxidant dosage | oxidant_dose | mg/l |
Mass flow rate of oxidant solution | chemical_flow_mass | kg/s |
Ratio of ozone to total organic carbon | ozone_toc_ratio | dimensionless |
Ratio of oxidant to ozone | oxidant_ozone_ratio | dimensionless |
Description | Constraint Name |
---|---|
Ozone consumption constraint | ozone_consumption_constraint |
Ozone mass flow constraint | ozone_flow_mass_constraint |
Ozone power constraint | electricity_constraint |
Ozone/TOC ratio constraint | ozone_toc_ratio_constraint |
Oxidant dose constraint | oxidant_dose_constraint |
Oxidant mass flow constraint | chemical_flow_mass_constraint |
.. index:: pair: watertap.unit_models.zero_order.ozone_aop_zo;ozone_aop_zo
.. currentmodule:: watertap.unit_models.zero_order.ozone_aop_zo
.. automodule:: watertap.unit_models.zero_order.ozone_aop_zo :members: :noindex: