Coagulation Flocculation (ZO)

Model Type

This unit model is formulated as a pass-through model form. See documentation for :ref:`pass-through Helper Methods<pt_methods>`.

Electricity Consumption

The constraint used to calculate energy consumption is described in the Additional Constraints section below. More details can be found in the unit model class.

Costing Method

Costing is calculated using the cost_coag_and_floc method in the zero-order costing package. See documentation for the :ref:`zero-order costing package<zero_order_costing>`.

Additional Variables

Description Variable Name Units
Dosing rate of alum alum_dose mg/l
Dosing rate of polymer polymer_dose mg/l
Ratio of anionic to cationic polymer in dosage anion_to_cation_polymer_ratio dimensionless
Dosing rate of anionic polymer anionic_polymer_dose mg/l
Dosing rate of cationic polymer cationic_polymer_dose mg/l
Mass flow rate of chemical solution chemical_flow_mass kg/s
Mass flow rate of chemical solution chemical_flow_mass kg/s
Rapid Mix Retention Time rapid_mix_retention_time s
Floc Retention Time floc_retention_time min
Rapid Mix Basin Volume rapid_mix_basin_vol m^3
Floc Basin Volume floc_basin_vol m^3
Number of Rapid Mixers num_rapid_mixers dimensionless
Number of Floc Mixers num_floc_mixers dimensionless
Number of Rapid Mix Processes num_rapid_mix_processes dimensionless
Number of Floc Processes num_floc_processes dimensionless
Number of Coagulation Processes num_coag_processes dimensionless
Number of Floc Injection Processes num_floc_injection_processes dimensionless
Rapid Mix Velocity Gradient velocity_gradient_rapid_mix 1/s
Floc Velocity Gradient velocity_gradient_floc 1/s
Rapid Mix Power Consumption power_rapid_mix kW
Floc Power Consumption power_floc kW
Total Power Consumption electricity kW

Additional Constraints

Description Constraint Name
None rapid_mix_basin_vol_constraint
None floc_basin_vol_constraint
None chemical_flow_constraint
None chemical_flow_constraint
None anionic_polymer_dose_constraint
None cationic_polymer_dose_constraint
Constraint for rapid mix power consumption rule_power_rapid_mix
Constraint for floc power consumption rule_power_floc
Total power consumption electricity_constraint
.. index::
   pair: watertap.unit_models.zero_order.coag_and_floc_zo;coag_and_floc_zo

.. currentmodule:: watertap.unit_models.zero_order.coag_and_floc_zo