Skip to content

Latest commit

 

History

History
38 lines (28 loc) · 2.08 KB

File metadata and controls

38 lines (28 loc) · 2.08 KB

NeoHub Binding

The NeoHub binding allows you to connect openhab via TCP/IP to Heatmiser's NeoHub and integrate your NeoStat thermostats onto the bus.

Binding Configuration

This binding can be configured in the file services/neohub.cfg.

The binding polls each thermostat that is configured in your items, at the refresh rate as set in the configuration.

Property Default Required Description
refresh 60000 No Refresh interval in milliseconds
hostname Yes the NeoHub network address
port 4242 No the port number for the NeoHub interface

Item Configuration

Item strings simply consist of two components - the NeoStat device name (as set in the thermostat and in the mobile app, e.g. Office), and the NeoStat property (e.g. CurrentTemperature). Both parameters are only separated by a colon. Some examples are below.

Switch Heating_Office       "Heating Office"         {neohub="Office:Heating"}
Switch Away_Office          "Away Office"            {neohub="Office:Away"}
Switch Standby_Office       "Standby Office"         {neohub="Office:Standby"}
Number Temperature_Office   "Temperature [%.1f °C]"  {neohub="Office:CurrentTemperature"}

The following properties, and their associated item types are shown below. The R and RW in the description column indicate which properties are read only (RO) or read/write (RW).

Property Type Supported Description
CurrentTemperature Number RO Current room temperature
CurrentSetTemperature Number RO Current set temperature
CurrentFloorTemperature Number RO Current floor temperature
DeviceName String RO Returns the device name
Heating Switch, String RO Returns ON or OFF if heating is currently enabled or not
Away Switch, String RW Returns ON or OFF if thermostat is in away mode or not
Standby Switch, String RW Returns ON or OFF if thermostat is in standby mode or not