Support for ITRON Water meter #468

Closed
heeplr opened this issue Feb 4, 2022 · 2 comments
Closed

Support for ITRON Water meter #468

heeplr opened this issue Feb 4, 2022 · 2 comments

Comments

@heeplr
Copy link

heeplr commented Feb 4, 2022

$ ./build/wmbusmeters 384497263003112103077a760000a00413b7130000066d2e17a9c422004413300f0000426cbf2c047f0000060c027f852a0e79678372082100
No meters configured. Printing id:s of all telegrams heard!
Received telegram from: 21110330
          manufacturer: (ITW) ITRON Water, France (0x2697)
                  type: Water meter (0x07)
                   ver: 0x03
                driver: unknown!

datagrams collected by rtl_433: itron.txt

@weetmuts
Copy link
Member

weetmuts commented Feb 6, 2022

@heeplr Did you see that Bibo create a driver for you?

@heeplr
Copy link
Author

heeplr commented Feb 6, 2022

Yes, and it works like a charm. Thank's a ton @BIBOLV !

@heeplr heeplr closed this as completed Feb 6, 2022