Skip to content

Latest commit

 

History

History
40 lines (24 loc) · 1017 Bytes

File metadata and controls

40 lines (24 loc) · 1017 Bytes

IPMI Firmware Update

The process for updating firmware on the IBM Power9 Server (Boston) is documented below.

Collect the required files

Collect the following files and put them into a directory on the Management Node.

  • pUpdate
  • pnor
  • bmc

If running rflash in Hierarchy, the firmware files/directory must be accessible on the Service Nodes.

Flash Firmware

Using xCAT rflash command, specify the directory containing the files with the -d option.

rflash <noderange> -d /path-to-directory/

The pUpdate utility is leveraged in doing the firmware update against the target node and will do the following:

  • power off the host
  • flash bmc and reboot
  • flash pnor
  • power on the host

Monitor the progress for the nodes by looking at the files under /var/log/xcat/rflash/.

Validatation

Use the rinv command to validate firmware level:

rinv <noderange> firm | xcoll