<?xml version="1.0"?>
<events>
<!-- Thresholds of XML-Collector -->
<event>
<uei>uei.opennms.org/cisco-apic/HighPolCamUsage-trigger</uei>
<event-label>The threshhold of the policer CAM table of a node in the Cisco APIC fabric was reached</event-label>
<descr>
%parm[description]%
</descr>
<logmsg dest="logndisplay">
Node %parm[instance]% of the APIC fabric has reached a critical point in policer CAM usage of %parm[value]% percent usage.
</logmsg>
<severity>Major</severity>
<alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%service%" alarm-type="1" auto-clean="false"/>
</event>
<event>
<uei>uei.opennms.org/cisco-apic/HighPolCamUsage-rearm</uei>
<event-label>The rearm threshhold of the policer CAM table of a node in the Cisco APIC fabric was reached</event-label>
<descr>
%parm[description]%
</descr>
<logmsg dest="logndisplay">
Node %parm[instance]% of the APIC fabric has fallen below the critical point in policer CAM usage of %parm[value]% percent usage.
The alarm has been cleared.
</logmsg>
<severity>Normal</severity>
<alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%service%" alarm-type="2" clear-key="uei.opennms.org/cisco-apic/HighPolCamUsage-trigger:%dpname%:%nodeid%:%interface%:%service%" auto-clean="false"/>
</event>
<!-- Created events by using send-event.pl -->
<event>
<uei>uei.opennms.org/cisco-apic/fault/Critical</uei>
<event-label>A critical fault on a Cisco APIC fabric was recognized</event-label>
<descr>
A critical fault on a Cisco APIC fabric was recognized </p>
%parm[descr]% </p>
</descr>
<logmsg dest="logndisplay">
%parm[all]%
</logmsg>
<severity>Critical</severity>
<alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[domain]%:%parm[code]%" alarm-type="1" auto-clean="true"/>
</event>
<event>
<uei>uei.opennms.org/cisco-apic/fault/Major</uei>
<event-label>A major fault on a Cisco APIC fabric was recognized</event-label>
<descr>
A major fault on a Cisco APIC fabric was recognized </p>
%parm[descr]% </p>
</descr>
<logmsg dest="logndisplay">
%parm[all]%
</logmsg>
<severity>Major</severity>
<alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[domain]%:%parm[code]%" alarm-type="1" auto-clean="true"/>
</event>
<event>
<uei>uei.opennms.org/cisco-apic/fault/Minor</uei>
<event-label>A minor fault on a Cisco APIC fabric was recognized</event-label>
<descr>
A minor fault on a Cisco APIC fabric was recognized </p>
%parm[descr]% </p>
</descr>
<logmsg dest="logndisplay">
%parm[all]%
</logmsg>
<severity>Minor</severity>
<alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[domain]%:%parm[code]%" alarm-type="1" auto-clean="true"/>
</event>
<event>
<uei>uei.opennms.org/cisco-apic/fault/Warning</uei>
<event-label>A warning on a Cisco APIC fabric was recognized</event-label>
<descr>
A warning on a Cisco APIC fabric was recognized </p>
%parm[descr]% </p>
</descr>
<logmsg dest="logndisplay">
%parm[all]%
</logmsg>
<severity>Warning</severity>
</event>
<event>
<uei>uei.opennms.org/cisco-apic/fault/Normal</uei>
<event-label>An event on a Cisco APIC fabric was recognized</event-label>
<descr>
An event on a Cisco APIC fabric was recognized </p>
%parm[descr]% </p>
</descr>
<logmsg dest="logndisplay">
%parm[all]%
</logmsg>
<severity>Normal</severity>
</event>