Hello
I did not update the IEEE. I change the current IEEE of the sonoff dongle P for the old one of my zigbee2mqtt network but it does not update it finishing without errors "All is OK. Restarting Zigbee

Thank you

@xyzroe
Copy link
Owner

xyzroe commented Aug 14, 2022

I need more information, screenshots, a more detailed description of what you have done. You didn't provide enough.

@gurues
Copy link
Author

gurues commented Aug 15, 2022

Hello, thanks for your interest. I attach a link with photos and video
https://drive.google.com/drive/folders/16NLz8deIrXXoNof4YD9eJ4qIpnNH_FvH?usp=sharing

@xyzroe
Copy link
Owner

xyzroe commented Aug 15, 2022

You must write ieee in one time with flashing.
It doesn't work if apply without flashing.

About your video - I think you upload wrong video.

@xyzroe xyzroe added the bug Something isn't working label Aug 15, 2022
@gurues
Copy link
Author

gurues commented Aug 16, 2022

Hello
I write ieee in one time with flashing but it does not work, at 20% of the process the previous IEEE is resumed. I attach video (avi and mp4 you may have to download to see them) and photos.

https://drive.google.com/drive/folders/1x9tGna6qe-hYMSEukpp313N7yqskTd-f?usp=sharing

Thank you very much for worrying about my problem and greetings

@xyzroe
Copy link
Owner

xyzroe commented Aug 22, 2022

Could you check JelmerT/cc2538-bsl#127 ?
I thinks it is yours situation.

@brugk000
Copy link

Hello,
I have the samen problem as @gurues with the zigstar lan gateway. IEEE is not updated during reflashing.

@xyzroe
Copy link
Owner

xyzroe commented Sep 19, 2022

@gurues @brugk000 This problem is not Multitool problem, but architecture of 2652. We can read only one address - primary one, but when we write it uses secondary one. zigbee2mqtt currently uses only primary one.

This is nicely covered in the JelmerT's issue I linked to earlier.