The code-checks are being triggered in jenkins. |
+code-checks |
A new Pull Request was created by @stahlleiton (Andre Stahl) for master. It involves the following packages: DQM/L1TMonitor @kmaeshima, @cmsbuild, @vanbesien, @vazzolini, @dmitrijus can you please review it and eventually sign? Thanks. cms-bot commands are listed here |
+1 |
The tests are being triggered in jenkins. |
This pull request is fully signed and it will be integrated in one of the next master IBs after it passes the integration tests. This pull request will now be reviewed by the release team before it's merged. @davidlange6, @slava77, @smuzaffar (and backports should be raised in the release meeting by the corresponding L2) |
+1 The following merge commits were also included on top of IB + this PR after doing git cms-merge-topic: |
Comparison job queued. |
Comparison is ready Comparison Summary:
|
+1 |
Description:
This PR includes the following changes:
Ignore BX range mismatch for EMTF to uGMT mismatch plot ( https://its.cern.ch/jira/browse/CMSLITDPG-340 )
The xmin and xmax values of uGMT_OMTFBXMeanAtBX0 are set to 0.15, and several QTs for uGMT are disabled in the L1T summary map ( https://its.cern.ch/jira/browse/CMSLITDPG-345 )
The maximally allowed muon TF data emulator mismatch is set the 1% ( https://its.cern.ch/jira/browse/CMSLITDPG-330 )
The summary map report is cleaned up (remove the empty QTs)