pfsense-ntp-gps

pfSense NTP GPS Server

SUMMARY

  • pfSense NTP GPS Stratum 1 Server

GPS status

PREREQUISITES

  • Mini PC with DE9 RS232 port with DCD input or a RJ45 COM port with the CTS input
  • Serial GPS receiver with PPS output

RECOMENDED HARDWARE

GPS RECEIVER

DE9 RS232 (DCD) MINI PC

RJ45 COM (CTS) MINI PC

COMPATIBILITY

INITIAL NTP CONFIG

  1. Configure pfSense NTP Time Servers: time.nist.gov, prefer, pool
  2. NTP Graphs: Enable RRD graphs
  3. Statistics Logging: reference clock, clock discipline
  4. Allow NTP to run for 24 hours to allow adequate time for the clock drift (a.k.a. freq) to settle. You may have to repeat this step after updating and/or reinstalling pfSense/FreeBSD

PPS ON CTS PIN

  1. FreeBSD UART Manual Page
  2. Disable Console Redirection in the BIOS and System -> Advanced -> Admin Access -> Serial Communication
  3. CTS tunable example:
    • System -> Advanced -> System Tunables -> New
    • Tunable Name -> dev.uart.0.pps_mode
    • Description -> 1=CTS, 2=DCD
    • Value -> 1
  4. Or, CTS loader example:
    • Create a /boot/loader.conf.local file
    • dev.uart.0.pps_mode="1"

GARMIN GPS CONNECTIONS

  1. Procure the following:

  2. The Garmin 16x LVS already has a RJ45 connector from the factory. Note: The remote ON/OFF pin #3 needs to be connected to RS232 or RJ45 ground pin #5.

  3. The Garmin 18x LVC has a JST connector from the factory, which can be re-terminated with a RJ45 connector with a similar pinout as the 16x for interchangeability. Note: There is 1x26 AWG black power ground wire, and 2x28 AWG black wires under the PVC jacket even though only one is terminated to the JST connector. Per Garmin Tech Support, both 28 AWG black wires are connected internally to the GPS module, thus only one needs to be connected to RS232 or RJ45 ground pin #5.

  4. The Garmin 17x HVS and 19x HVS have bare leads and requires unregulated 8-33 Vdc, thus you can power it from the same 12 Vdc power supply as the Mini PC. I terminated the GPS 19x cable to a surface mount Ethernet jack.

  5. Build a cable to provide power, RS232 communication, and PPS signal. pinout cable gps19x

NTP SETTINGS

  • Services -> NTP -> Settings
  • Enable NTP Server -> 1
  • Interface -> LAN, Localhost
  • Time Severs
    • time.nist.gov
    • Pool
  • NTP Graphs-> Enable RRD graphs of NTP statistics -> 1
  • Statistics Logging
    • Log reference clock statistics -> 1
    • Log clock discipline statistics -> 1
    • Log NTP peer statistics -> 1

NTP GPS SETTINGS EXAMPLE

  • Services -> NTP -> Serial GPS
  • Type -> Garmin
  • Serial Port -> cuau0
  • Baud -> 38400
  • Check baud rate before sending init commands -> 1
  • NMEA Messages -> All
  • Fudge Time 1 -> 0.0013
  • Fudge TIme 2 -> 0.369
  • Minimum Poll Interval -> 3: 8 seconds
  • Maximum Poll Interval -> 3: 8 seconds
  • Prefer this clock -> 1
  • Enable PPS signal processing -> 1
  • Enable kernel PPS clock discipline -> 1
  • Log the sub-second fraction of the received time stamp -> 1
  • Display extended GPS status -> 1
  • GPS Initialization
    • $PGRMC,A,4,18,,,,,,,8,,2,4,*09
    • $PGRMC1,1,1,,,,,,N,N,,,,1,,2*55
    • $PGRMO,,2*75
    • $PGRMO,GPGGA,1*20
    • $PGRMI,,,,,,,R*3F
  • Auto correct malformed initialization commands -> 1

USEFUL NTP CLI COMMANDS

  • ntpq -pn
  • ntpq -c kerninfo
  • ntpq -c sysinfo
  • ntptime

PFSENSE FIREWALL RULE

rule

CLOCK OFFSET RESULTS

loopstats

LCDPROC LCD DISPLAY (OPTIONAL)

  1. You can optionally add a LCD display, install the LCDproc package, and enable the NTP status screen
    • Services -> LCDproc -> Screens -> Display NTP Status

SUGGESTED LCD DISPLAY

  1. Crystalfontz XES635 LCD USB Display in Steel Enclosure
  2. LCDproc server settings example:
    • Services -> LCDproc -> Server
    • COM port -> /dev/cuaU0
    • Display Size -> 4 rows 20 columns
    • Driver -> CrystalFontz Packet
    • Port Speed -> Default

LCDPROC NTP SCREEN NOTES

  • I am by no means a NTPD algorithm expert, but I noticed if a source is marked as a valid PPS Peer "o", NTPD uses that to sync and serve time to clients regardless if there a separate Active Peer "*" used for time data. If a GPS is being used for both a PPS Peer "o"and source of time data, it will be marked as PPS Peer "o" and there will be no other Active Peers "*" marked. The NTP Widget seems to display the Active Peer "*" even when the PPS Peer "o" is actually being used to sync and serve time to clients. Which source is actually served to clients can be confirmed with "ntpq -c sysinfo". If you want to see the stability value when using a GPS with PPS, you can simply set the Clock ID of the GPS source to "PPS". I intentionally did not include seconds on the display since even with the LCDProc Refresh Frequency set to 1 second, time will jump multiple seconds with each screen refresh. Not sure if there is another mechanism that would improve the refresh rate of the first row to eliminate increments of multiple seconds.

LCDPROC NTP SCREENS

gps pps ip

About

pfSense NTP GPS Server