Skip to content

pierremolinaro/can20B-plugin-for-saleae-logic-analyzer

Repository files navigation

CAN 2.0B (Molinaro): Controller Area Network (CAN) Analyzer for Saleae Logic 2 Analyzer

This is a plugin for Saleae Logic 2 Analyzers, built with Saleae Analyzer SDK. From July 22, 2022, it uses FrameV2 so it can be used only with Saleae Logic 2.3.43 or newer.

Building the plugin

For building the plugin, see https://github.com/saleae/SampleAnalyzer

Generating Analyzer Simulation Data

(From https://github.com/saleae/SampleAnalyzer)

The Logic 2 software will need to be opened from the terminal using a specific command to enable simluation mode. Otherwise, by default, when an analyzer is added to digital channels while in Demo mode (i.e. no Logic is connected to the PC), the simulation data on those digital channels will contain seemingly random transitions and will not contain analyzer-specific data.

For instructions on enabling simulation mode on the Logic 2 software, please follow the instructions here: https://support.saleae.com/user-guide/using-logic/demo-mode#generating-analyzer-simulation-data

How to permanently enable simulation on Mac OS X

Here is a trick for permanently enabling simulation on Mac OS X. Just copy the name.pcmolinaro.saleaeEnableSimulation.plist file (located in enable-simulation-on-osx directory) in your ~/Library/LaunchAgents directory. Then log out then log in (or restart), it is done, simulation is permanently enabled.

For permanently disabling this feature, delete ~/Library/LaunchAgents/name.pcmolinaro.saleaeEnableSimulation.plist and log out then log in (or restart).

Selecting Analyzer

The analyzer Name is CAN 2.0B (Molinaro).

Setting Dialog

Plugin settings

Setting Dialog

CAN Bit Rate

Usual CAN bit rates settings are 1000000 (1 Mbit/s), 500000 (500 kbit/s), 250000 (250 kbit/s), 125000 (125 kbit/s), 62500 (62.5 kbit/s). But you can use any custom setting (maximum is 1 Mbit/s).

Dominant Logic Level

Usually, CAN Dominant level is LOW logic level. This setting enables selecting HIGH as dominant level.

Simulator Random Seed

This setting is only used be the simulator. The simulator is enabled when no device is connected the analyzer.

The simulator generates random frames. This setting defines the initial value of this parameter, making frame generation reproducible.

Simulator Generated Frames Format

This setting is only used be the simulator. The simulator is enabled when no device is connected the analyzer.

You can set the format (standard / extended) and the the type (data / remote) that the simulator generates:

  • All Types: the simulator randomly generates standard / extended, data / remote frames;
  • Only Standard Data Frames: the simulator randomly generates standard data frames;
  • Only Extended Data Frames: the simulator randomly generates extended data frames;
  • Only Standard Remote Frames: the simulator randomly generates standard remote frames;
  • Only Extended Remote Frames: the simulator randomly generates extended remote frames.

Simulator ACK SLOT generated level

This setting is only used be the simulator. The simulator is enabled when no device is connected the analyzer.

The ACK SLOT field of a CAN 2.0B frame is sent recessive, and set dominant by any receiver that gets the frame without any error.

Three settings are available:

  • Dominant: the simulator generates frames with the ACK SLOT bit dominant;
  • Recessive: the simulator generates frames with the ACK SLOT bit recessive;
  • Random: the simulator generates frames with the ACK SLOT bit randomly dominant or recessive.

Simulator Generated Frames Validity

This setting is only used be the simulator. The simulator is enabled when no device is connected the analyzer.

The simulator can generate valid frames, or frames with errors.

Two settings are available:

  • Generate Valid Frames: the simulator generates valid frames;
  • Randomly toggle one bit: in every generated frame, one random bit is inverted.

Capture Display

This is the capture of a Standard data frame, identifier 0x40C, one data byte (0xF3), with ACK SLOT dominant.

By default, the center of a bit is indicated with a dot.

The green dot is the SOF (Start Of Frame) field.

The orange square is an IDLE bit (from release 1.1.0).

A white X is a Stuff Bit.

A fixed form bit is denoted by a 0 (for a dominant bit) or a 1 (recessive bit). Note the level inversion does not change the annotation.

The RTR and the SRR bits are denoted by an up arrow (if recessive), or a down arrow (if dominant).

A recessive ACK SLOT bit is marked with a red X, an active one with a down arrow.

Errors are in red color: a red X is a Stuff Error, and following bits are tagged with red dots until the bus returns free (11 consecutive recessive bits).

Bubble Text

The bubble text is the text over the capture.

All CAN frames fields are reported, but:

  • the SOF field that is denoted by a green dot.
  • the CRC DEL field, a fixed form recessive bit after the CRC field.

If a CRC error is detected, the text is CRC: xxx (error).

Terminal

For each frame, the terminal contains:

  • the identifier;
  • the data bytes;
  • if there is a CRC error, the CRC field;
  • the frame bit length, its duration, and the number of stuff bits.

Data Table