Skip to content
Permalink
Browse files
platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs
Siemens industrial PCs unfortunately can not always be properly
identified the way we used to. An earlier commit introduced code that
allows proper identification without looking at DMI strings that could
differ based on product branding.
Switch over to that proper way and revert commits that used to collect
the machines based on unstable strings.

Fixes: 648e921 ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Fixes: e8796c6 ("platform/x86: pmc_atom: Add Siemens CONNECT ...")
Fixes: f110d25 ("platform/x86: pmc_atom: Add Siemens SIMATIC ...")
Fixes: ad0d315 ("platform/x86: pmc_atom: Add Siemens SIMATIC ...")
Tested-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Henning Schild <henning.schild@siemens.com>
  • Loading branch information
henning-schild authored and intel-lab-lkp committed Mar 15, 2021
1 parent 2cc27e0 commit 7b3ce3514b5f314b15ab6e2898104fa3e8e76d59
Showing 1 changed file with 27 additions and 20 deletions.
@@ -13,6 +13,7 @@
#include <linux/io.h>
#include <linux/platform_data/x86/clk-pmc-atom.h>
#include <linux/platform_data/x86/pmc_atom.h>
#include <linux/platform_data/x86/simatic-ipc.h>
#include <linux/platform_device.h>
#include <linux/pci.h>
#include <linux/seq_file.h>
@@ -362,6 +363,23 @@ static void pmc_dbgfs_register(struct pmc_dev *pmc)
}
#endif /* CONFIG_DEBUG_FS */

static bool pmc_clk_is_critical = true;

static int siemens_clk_is_critical(const struct dmi_system_id *d)
{
u32 st_id;

if (dmi_walk(simatic_ipc_find_dmi_entry_helper, &st_id))
goto out;

if (st_id == SIMATIC_IPC_IPC227E || st_id == SIMATIC_IPC_IPC277E)
return 1;

out:
pmc_clk_is_critical = false;
return 1;
}

/*
* Some systems need one or more of their pmc_plt_clks to be
* marked as critical.
@@ -424,24 +442,10 @@ static const struct dmi_system_id critclk_systems[] = {
},
},
{
.ident = "SIMATIC IPC227E",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
},
},
{
.ident = "SIMATIC IPC277E",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
},
},
{
.ident = "CONNECT X300",
.callback = siemens_clk_is_critical,
.ident = "SIEMENS AG",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
},
},

@@ -453,17 +457,20 @@ static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
{
struct platform_device *clkdev;
struct pmc_clk_data *clk_data;
const struct dmi_system_id *d = dmi_first_match(critclk_systems);
const struct dmi_system_id *d;

clk_data = kzalloc(sizeof(*clk_data), GFP_KERNEL);
if (!clk_data)
return -ENOMEM;

clk_data->base = pmc_regmap; /* offset is added by client */
clk_data->clks = pmc_data->clks;
if (d) {
clk_data->critical = true;
pr_info("%s critclks quirk enabled\n", d->ident);
if (dmi_check_system(critclk_systems)) {
clk_data->critical = pmc_clk_is_critical;
if (clk_data->critical) {
d = dmi_first_match(critclk_systems);
pr_info("%s critclks quirk enabled\n", d->ident);
}
}

clkdev = platform_device_register_data(&pdev->dev, "clk-pmc-atom",

0 comments on commit 7b3ce35

Please sign in to comment.