mqtt-eneregenie-ener314rt Change Log

[Unreleased]

  • Periodic eTRV commands #10
  • Update state of all OOK switches within a single device when switch 0 used #4
  • Enhance availability (or publish guidance) on OpenThings devices based on last_seen

Also see Issues for additional details.

[0.7.1] 2024-02

Added

  • Support added for MiHome Thermostat (MIHO069), including auto-messaging
  • MQTT Discovery: Added thermostat, including Climate Control entity
  • The number of retries is now configurable for cached commands (applies to eTRV and thermostat) by setting cache_retries in config,json (default remains at 10)
  • MQTT Discovery: Added 'Battery Timestamp' (mapped to MQTT VOLTAGE_TS) and 'Diagnostics Ran' (mapped to DIAGNOSTICS_TS) for eTRV
  • MQTT Discovery: Added 'Identify' Button for eTRV
  • Setting target temperature now caters for 0.5 increments (was integer)
  • A different mechanism of reporting processed commands has been implemented for the thermostat. When (and only when) the thermostat procesess a command it outputs it's telemetry data. This mechanism has been used to assume that the command just sent to the device (upon WAKEUP) has been processed succesfully; and it is the command has it's retained state set in MQTT [#61](#61

Fixed

  • Added options to mqtt service for increased resillience of restarting the service upon failure #62(@genestealer)
  • Removed verbose logging of MQTT password #66

Changed

  • Pretty printed all device JSON files
  • MQTT Discovery: OEM Part Number and Device ID added to HA device model field (@genestealer)
  • Bumped energenie-ener314rt to v0.7.1 (REQUIRED)
  • Submitting a cached command will now replace the exisiting cached command for the device
  • Added data value to the reporting of command when it has been succesfully cached (also only update MQTT when this is set to 0=None) #69, e.g. "Set Temperature" becomes "Set Temperature 18.5"

See also: https://github.com/Achronite/energenie-ener314rt/releases/tag/v0.7.0 - Notably pi5 support and GPIO driver changes

[0.6.0] 2023-11-13

Added

  • Extra keys '433MHz' and 'MiHome' added to package.json (@genestealer)
  • Instructions added to README for joining undiscovered Monitor devices #52

Fixed

  • Type error on Maintenance LOW_POWER_MODE causing crash #49

Changed

  • MQTT Discovery: Entity names are now in Title Case (instead of all lower case)
  • MQTT Discovery: eTRV Climate now operates differently to align closer to the Climate modes in Home Assistant #47 (note: the numbers in brackets show the equivalent eTRV VALVE_STATE)
    • 'auto' (2) mode in HA means it is run by an external schedule, so has therefore been removed as not applicable
    • 'heat' (was 0 now 2) mode operates to the set-point temperature
    • 'off' (1) mode unchanged
    • 'always on' (0) has been removed, as there isn't an equivalent in HA
  • MQTT Discovery: Origin added to device discovery message (@genestealer)
  • MQTT Discovery: Device Class for Smart Plug switch set to outlet (@genestealer)
  • MQTT Discovery: eTRV REPORTING_INTERVAL and Maintenance Entity categories set to config (@genestealer)
  • MQTT Discovery: eTRV temperature step added and set to 0.5 (@genestealer)
  • MQTT Discovery: Battery % now shows as dynamic icon in Home Assistant for eTRV (@genestealer) and Home Energy Monitor (@Achronite)
  • MQTT Discovery: FREQUENCY and VOLTAGE added as HA 'disabled entities' for Monitor Plug, and Smart Plug+

[0.5.1] 2023-08-16 Alpha

Fixed

  • Battery level calculation modified (again) to prevent values above 100% #37

Changed

  • Software version added to the startup log message and the sw_version for HA discovery (@webash)
  • MQTT Discovery: 'Energenie' capitalised in manufacturer (@webash)

[0.5.0] 2023-08-11 Alpha

Added

  • Configurable levels of logging within the application #24.
    The log level can now be configured in the config.json file using log_level. The file is read once on startup. The default log_level is http, which logs all incoming and outgoing commands/messages.

Fixed

  • Simplified algorithm for battery % calculation. Tries to close #31
  • Fixed a bug where the target switch state sometimes fails to be updated in MQTT for OOK devices due to a bug in dependency energenie-ener314rt#32
  • Fixed a bug where a stack trace was sometimes output for MQTT connection when exiting application

Changed

  • Dependencies: Bumped MQTT.js version to 5.0.2 and node.js minimum version to 15. #38

[0.4.0] 2023-08-07 Alpha

Added

  • Translated ALARM: 66 to ALARM: Low battery alert. Fixes #28

Fixed

  • MQTT Discovery: Battery missing unit of measurement. Fixes #30
  • MQTT Discovery: Removed name of entity from the device name. Fixes #34

[0.3.0] 2023-03-06 Alpha

Added

  • Added device section to manual MQTT setup for Home Assistant (to assist in HA automations)
  • Added estimated battery topics for eTRV and Whole house monitor [#17]
  • Renamed default config.json file to config_sample.json to prevent user config overwrites upon update of code
  • MQTT Discovery: Added ALARM reportng for PIR, it is believed a value of 66 = Low battery alert See #28

Fixed

  • Fixed README instructions for install
  • MQTT Discovery: Renamed measurement unit VAR to var for devices #[#25]
  • MQTT Discovery: Fixed REPORTING_INTERVAL device_class [#26] for eTRV

[0.2.0] 2023-01-31 Alpha

Added

  • Grouped a devices parameters for HA MQTT discovery #15
  • Request Voltage added to Maintenance commands for eTRV
  • Added 'last_seen' topic as epoch for all OpenThings devices at device level #18
  • Guidance added to README for formatting epoch timestamps in Home Assistant
  • Added overall availability of application, including basing all discovery devices on this overall availability topic #19
  • Implemented 'climate' card for applicable eTRV parameters in MQTT discovery #16
  • Config values added for OOK and FSK xmits (excluding cached_cmds for eTRV) #21

Changed

  • Replaced underscores with spaces for MQTT discovery entity names
  • Reduced MQTT discovery message lengths by expanding '~' to include the device type and id
  • Set retain flag on irregular reported values on MQTT for 'VALVE_STATE', 'LOW_POWER_MODE', 'REPORTING_INTERVAL', 'TARGET_TEMP' & 'ERROR_TEXT'
  • Simplified state/command values for VALVE_STATE to be 0,1,2 (Maintenance cmds unchanged)

Fixed

  • Issue in MQTT discovery that prevented battery voltage being shown for eTRV and House Energy monitor

[0.1.0] 2023-01-25 Alpha

Added

  • Initial packaged release, logging remains for all MQTT inputs & outputs in this version
  • Support for switched OOK devices is included
  • Switch support for MiHome Adaptor+ included
  • MiHome PIR & Door Sensor supported
  • Async monitoring of all known parameters for FSK/OpenThings devices is included
  • Home Assistant MQTT Discovery added for MiHome devices:
    • Monitor Plug
    • Smart Plug+
    • Radiator Valve (includes simplified commands using 'Maintenance' dropdown)
    • Whole House Monitor
    • Door (Contact) Sensor
    • PIR