Notifications
You must be signed in to change notification settings - Fork 3
/
A3COM-HUAWEI-ENTITY-EXT-MIB
executable file
·1533 lines (1391 loc) · 55.2 KB
/
A3COM-HUAWEI-ENTITY-EXT-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
-- =================================================================
-- Copyright (c) 2004-2012 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: description of entity extend properties.
-- Reference:
-- History V2.8
-- V1.0 Created by weixinzhe, Thursday, April 22, 2004 at 18:26:02
-- V1.1 modified by yelinhui, add h3cEntityExtMacAddress
-- V1.2 modified by panxidong, add h3cEntityExtErrorStatus
-- V1.3 2004-10-12 updated by gaolong
-- Remove BITS from IMPORTS
-- V1.4 2005-02-25 modified by longyin
-- Add error status stackPortBlocked(22) and stackPortFailed(23)
-- for h3cEntityExtErrorStatus
-- V1.5 2006-05-16 modified by wangsihai
-- Add error status sensorError(81) in h3cEntityExtErrorStatus
-- V1.6 2006-07-03 modified by lifengguang
-- Add h3cEntityExtManuTable
-- V1.7 2007-09-21 modified by lifengguang
-- Add notification object h3cEntityExtSFPAlarmOn and h3cEntityExtSFPAlarmOff
-- Add h3cEntityExtPowerTable
-- V1.8 2007-11-19 modified by jinyi
-- Add h3cEntityExtCpuMaxUsage
-- V1.9 2008-02-27 modified by lifengguang
-- Add Trap nodes: h3cEntityExtSFPPhony
-- V2.0 2008-07-11 modified by lisong
-- Add h3cProcessTable
-- Add notification object h3cEntityInsert and h3cEntityRemove
-- V2.1 2008-07-14 modified by lifengguang
-- Add error status hardwareFaulty(91) in h3cEntityExtErrorStatus
-- Add Trap nodes: h3cEntityExtForcedPowerOff and h3cEntityExtForcedPowerOn
-- Add Trap nodes: h3cEntityExtFaultAlarmOn and h3cEntityExtFaultAlarmOff
-- V2.2 2008-10-24 modified by lifengguang
-- Add nodes h3cEntityExtLowerTemperatureThreshold and
-- h3cEntityExtShutdownTemperatureThreshold in h3cEntityExtStateTable
-- Add trap nodes h3cEntityExtResourceLack and h3cEntityExtResourceEnough
-- in h3cEntityExtTrapsPrefix
-- Add trap nodes h3cEntityExtTemperatureLower, h3cEntityExtTemperatureTooUp
-- and h3cEntityExtTemperatureNormal in h3cEntityExtTrapsPrefix
-- V2.3 2009-04-07 Added trap nodes h3cEntityExternalAlarmOccur and
-- h3cEntityExternalAlarmRecover
-- v2.4 2009-05-05 Added h3cEntityExtCpuAvgUsage, h3cEntityExtMemAvgUsage,
-- h3cEntityExtPhyMemSize, h3cEntityExtMemType, h3cEntityExtPhyCpuFrequency,
-- h3cEntityExtFirstUsedDate,
-- h3cEntityExtCpuUsageThresholdRecover, h3cEntityExtMemUsageThresholdRecover
-- V2.5 2010-08-09
-- Added h3cEntityExtShutdownLowerTemperatureThreshold,
-- h3cEntityExtCriticalLowerTemperatureThreshold,
-- h3cEntityExtCritLowerTempThresholdNotification and
-- h3cEntityExtTemperatureTooLow by zhanglei 06807.
-- Added h3cEntityExtMemAllocatedFailed, h3cEntityExtECCParityAlarm,
-- h3cEntityExtTrapDescription, h3cEntityExtECCParityAlarmStatus
-- by zhangqingjun 02357.
-- Modified description of h3cEntityExtPhyMemSize by haoyan 06611.
-- V2.6 2010-12-06
-- Added h3cEntityExtFanDirectionNotPreferred, h3cEntityExtFanDirectionNotAccord
-- by lifengguang 03035.
-- V2.7 2011-04-06
-- Added h3cEntityExtSFPInvalid, h3cEntityExtSFPInvalidNow and
-- h3cEntityExtSFPInvalidInDays by songhao 02718.
-- Changed SYNTAX of h3cEntityExtMemSize and h3cEntityExtPhyMemSize
-- from Integer32 to Unsigned32 by songhao 02718.
-- V2.8 2011-08-30
-- Added h3cEntityExtCpuUsageRecoverThreshold;
-- Added h3cEntityExtCpuUsageRecoverThreshold to h3cEntityExtCpuUsageThresholdNotfication and
-- h3cEntityExtCpuUsageThresholdRecover by shuaixiaojuan 04117.
-- Added h3cEntityExtFirstTrapTime by duyanbing 04404.
-- =================================================================
A3COM-HUAWEI-ENTITY-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
h3cCommon
FROM A3COM-HUAWEI-OID-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32,
Unsigned32, Gauge32, TimeTicks
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, MacAddress, DateAndTime, DisplayString
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
entPhysicalIndex, entPhysicalName, entPhysicalDescr
FROM ENTITY-MIB;
h3cEntityExtend MODULE-IDENTITY
LAST-UPDATED "201111260000Z"
ORGANIZATION
"Hangzhou H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip: 100085"
DESCRIPTION
"The private MIB file includes the general extent
information of the device."
::= { h3cCommon 6 }
H3cAdminState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The administrative state for this object, and it is possible to
set the state when needed.
A value of locked means the resource is administratively prohibited
from use. A value of shuttingDown means that usage is
administratively limited to current instances of use.
A value of unlocked means the resource is not administratively
prohibited from use."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX INTEGER
{
notSupported(1),
locked(2),
shuttingDown(3),
unlocked(4)
}
H3cOperState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" Represents the possible values of operational states.
A value of disabled means the resource is totally
inoperable. A value of enabled means the resource
is partially or fully operable."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX INTEGER
{
notSupported (1),
disabled(2),
enabled(3),
dangerous(4)
}
H3cAlarmStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the possible values of alarm status.
When no bits of this attribute are set, then none of the
status conditions described below are present. When the
value of under repair is set, the resource is currently
being repaired.
When the value of critical is set, one or more critical
alarms are active against the resource. When the value of
major is set, one or more major alarms are active against
the resource. When the value of minor is set, one or more
minor alarms are active against the resource. When the
value of warning is set, one or more warning alarms are
active against the resource. When the value of
indeterminate is set, one or more alarms of indeterminate
severity are active against the resource.
When the value of alarm outstanding is set, one or more
alarms is active against the resource. The fault may or may
not be disabling."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX BITS
{
notSupported (0),
underRepair(1),
critical(2),
major(3),
minor(4),
alarmOutstanding(5),
warning (6), -- Not defined in X.731
indeterminate (7) -- Not defined in X.731
}
H3cStandbyStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" Represents the possible values of standby status.
A value of hotStandby means the resource is not providing
service, but is will be immediately able to take over the
role of the resource to be backed-up, without the need for
initialization activity, and will contain the same
information as the resource to be backed up. A value of
coldStandy means that the resource is to back-up another
resource, but will not be immediately able to take over
the role of a resource to be backed up, and will require
some initialization activity. A value of providingService
means the resource is providing service."
REFERENCE
"ITU Recommendation X.731, 'Information Technology - Open
Systems Interconnection - System Management: State
Management Function', 1992"
SYNTAX INTEGER
{
notSupported (1),
hotStandby(2),
coldStandby(3),
providingService(4)
}
h3cEntityExtObjects OBJECT IDENTIFIER ::= { h3cEntityExtend 1 }
-- MIB contains four groups
h3cEntityExtState OBJECT IDENTIFIER ::= { h3cEntityExtObjects 1 }
h3cEntityExtStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cEntityExtStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per physical entity, There is
always at least one row for an 'overall' physical entity.
The information in each row may be not include all the object
in this table, because of the entity need not some of the
information here."
::= { h3cEntityExtState 1 }
h3cEntityExtStateEntry OBJECT-TYPE
SYNTAX H3cEntityExtStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about a particular physical entity."
INDEX { h3cEntityExtPhysicalIndex }
::= { h3cEntityExtStateTable 1 }
H3cEntityExtStateEntry ::= SEQUENCE {
h3cEntityExtPhysicalIndex
Integer32,
h3cEntityExtAdminStatus
H3cAdminState,
h3cEntityExtOperStatus
H3cOperState,
h3cEntityExtStandbyStatus
H3cStandbyStatus,
h3cEntityExtAlarmLight
H3cAlarmStatus,
h3cEntityExtCpuUsage
Integer32,
h3cEntityExtCpuUsageThreshold
Integer32,
h3cEntityExtMemUsage
Integer32,
h3cEntityExtMemUsageThreshold
Integer32,
h3cEntityExtMemSize
Unsigned32,
h3cEntityExtUpTime
Integer32,
h3cEntityExtTemperature
Integer32,
h3cEntityExtTemperatureThreshold
Integer32,
h3cEntityExtVoltage
Integer32,
h3cEntityExtVoltageLowThreshold
Integer32,
h3cEntityExtVoltageHighThreshold
Integer32,
h3cEntityExtCriticalTemperatureThreshold
Integer32,
h3cEntityExtMacAddress
MacAddress,
h3cEntityExtErrorStatus
INTEGER,
h3cEntityExtCpuMaxUsage
Integer32,
h3cEntityExtLowerTemperatureThreshold
Integer32,
h3cEntityExtShutdownTemperatureThreshold
Integer32,
h3cEntityExtPhyMemSize
Unsigned32,
h3cEntityExtPhyCpuFrequency
Integer32,
h3cEntityExtFirstUsedDate
DateAndTime,
h3cEntityExtCpuAvgUsage
Integer32,
h3cEntityExtMemAvgUsage
Integer32,
h3cEntityExtMemType
OCTET STRING,
h3cEntityExtCriticalLowerTemperatureThreshold
Integer32,
h3cEntityExtShutdownLowerTemperatureThreshold
Integer32,
h3cEntityExtCpuUsageRecoverThreshold
Integer32
}
h3cEntityExtPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of h3cEntityExtStateTable.
This index is identical to entPhysicalIndex in ENTITY-MIB"
::= { h3cEntityExtStateEntry 1 }
h3cEntityExtAdminStatus OBJECT-TYPE
SYNTAX H3cAdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for this object."
::= { h3cEntityExtStateEntry 2 }
h3cEntityExtOperStatus OBJECT-TYPE
SYNTAX H3cOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operate state for this object."
::= { h3cEntityExtStateEntry 3 }
h3cEntityExtStandbyStatus OBJECT-TYPE
SYNTAX H3cStandbyStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used for monitoring standby status.
Not all entities support this object."
::= { h3cEntityExtStateEntry 4 }
h3cEntityExtAlarmLight OBJECT-TYPE
SYNTAX H3cAlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm status for this entity. It does not include
the severity of alarms raised on child components. In
this condition, there will be a alarm light on the entity,
the object should have the same status with it."
::= { h3cEntityExtStateEntry 5 }
h3cEntityExtCpuUsage OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU usage for this entity. Generally, the CPU usage
will calculate the overall CPU usage on the entity, and it
is not sensible with the number of CPU on the entity."
::= { h3cEntityExtStateEntry 6 }
h3cEntityExtCpuUsageThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the CPU usage. When the CPU usage exceeds
the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 7 }
h3cEntityExtMemUsage OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory usage for the entity. This object indicates what
percent of memory are used."
::= { h3cEntityExtStateEntry 8 }
h3cEntityExtMemUsageThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the Memory usage, When the memory usage
exceeds the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 9 }
h3cEntityExtMemSize OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of memory for the entity."
::= { h3cEntityExtStateEntry 10 }
h3cEntityExtUpTime OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The uptime for the entity. The meaning of uptime is
when the entity is up, and the value of the object
will add 1 seconds while the entity is running."
::= { h3cEntityExtStateEntry 11 }
h3cEntityExtTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature for the entity."
::= { h3cEntityExtStateEntry 12 }
h3cEntityExtTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the temperature. When the temperature
exceeds the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 13 }
h3cEntityExtVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage for the entity."
::= { h3cEntityExtStateEntry 14 }
h3cEntityExtVoltageLowThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The low-threshold for the voltage.
When voltage is lower than low-threshold, a notification will be
sent."
::= { h3cEntityExtStateEntry 15 }
h3cEntityExtVoltageHighThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The high-threshold for the voltage.
When voltage greater than high-threshold, a notification will be
sent."
::= { h3cEntityExtStateEntry 16 }
h3cEntityExtCriticalTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The threshold for the critical Temperature. When temperature
exceeds the critical temperature, a notification will be sent."
::= { h3cEntityExtStateEntry 17 }
h3cEntityExtMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address of the entity."
::= { h3cEntityExtStateEntry 18 }
h3cEntityExtErrorStatus OBJECT-TYPE
SYNTAX INTEGER
{
notSupported(1),
normal(2),
postFailure(3),
entityAbsent(4),
poeError(11),
stackError(21),
stackPortBlocked(22),
stackPortFailed(23),
sfpRecvError(31),
sfpSendError(32),
sfpBothError(33),
fanError (41),
psuError(51),
rpsError(61),
moduleFaulty(71),
sensorError(81),
hardwareFaulty(91)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the error state of this entity object. Now it only
supports Port, general power supply, RPS power supply and
board/Subcard. It may have one of these values.
The following four values can be used for all kinds of entities.
notSupported(1) means this entity can not support this function.
normal(2) means the statement of this entity is normal. for ports,
it doesn't differentiate 10M/s, 100M/s, 1000M/s, duplex and
half-duplex. For fan, power supply and board-Subcard, it means
their states are normal.
postFailure(3) means the entity fails to POST.
entityAbsent(4) means the entity is absent now.
The following values is depended on the entity .
For Port entities, it may have the following values. If its POST
is failure,
then the value of the instance will be postFailure(3), otherwise
the value will be normal(2).
If enable power supply over Ethernet on this port is failure,
the value of this instance will be poeError(11), otherwise it will
be normal(2).
For stack port, if it connects to another stack port normally, and
these two units merge into one stack, then the value of this
instance will be normal(2).
If something wrong occurs and the unit can not merge into stack,
the value of this instance will be stackPortFailed(23). If the
stack port forms resilient daisy chain with another stack port
on the other unit, the value of this instance will be
stackPortBlocked(22).
For SFP ports, if it fail to receive, the value of this instance
will be sfpRecvError(31), if it fail to send, the value is
sfpSendError(32), if it fail to send and receive, the value is
sfpBothError(33), otherwise it will be normal(2).
fanError(41) means that the fan stops working.
psuError(51) means that the Power Supply Unit is in the state of
fault.
rpsError(61) means the RPS is in the state of fault.
moduleFaulty(71) means the Module is in the state of fault.
sensorError(81) means the sensor is in the state of fault.
hardwareFaulty(91) means the hardware of specified entity is in the state of fault.
NMS must be compatible with the states which may be added
in the future."
::= { h3cEntityExtStateEntry 19 }
h3cEntityExtCpuMaxUsage OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximal CPU usage for the entity in the period of time."
::= { h3cEntityExtStateEntry 20 }
h3cEntityExtLowerTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the lower Temperature. When temperature runs
under the threshold, a notification will be sent."
::= { h3cEntityExtStateEntry 21 }
h3cEntityExtShutdownTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the shutdown Temperature. When temperature
exceeds the threshold, a notification will be sent and the entity
will be shutdown."
::= { h3cEntityExtStateEntry 22 }
h3cEntityExtPhyMemSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory size of entity. This is the physical attribute of entity."
::= { h3cEntityExtStateEntry 23 }
h3cEntityExtPhyCpuFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU frequency of entity. Unit of measure is MHZ."
::= { h3cEntityExtStateEntry 24 }
h3cEntityExtFirstUsedDate OBJECT-TYPE
SYNTAX DateAndTime (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first used date of the entity."
::= { h3cEntityExtStateEntry 25 }
h3cEntityExtCpuAvgUsage OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average CPU usage for the entity in a period of time."
::= { h3cEntityExtStateEntry 26 }
h3cEntityExtMemAvgUsage OBJECT-TYPE
SYNTAX Integer32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average memory usage for the entity in a period of time."
::= { h3cEntityExtStateEntry 27 }
h3cEntityExtMemType OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory type of entity."
::= { h3cEntityExtStateEntry 28 }
h3cEntityExtCriticalLowerTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the critical Temperature. When temperature
exceeds the critical lower temperature, a notification will be sent."
::= { h3cEntityExtStateEntry 29 }
h3cEntityExtShutdownLowerTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for the shutdown Temperature. When temperature
exceeds the lower threshold, a notification will be sent and the entity
will be shutdown."
::= { h3cEntityExtStateEntry 30 }
h3cEntityExtCpuUsageRecoverThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recover threshold for the CPU usage. When the CPU usage falls down to
the threshold, a notification is sent. The h3cEntityExtCpuUsageRecoverThreshold
must be less than or equal to the h3cEntityExtCpuUsageThreshold."
DEFVAL { 100 }
::= { h3cEntityExtStateEntry 31 }
h3cEntityExtManu OBJECT IDENTIFIER ::= { h3cEntityExtObjects 2 }
h3cEntityExtManuTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cEntityExtManuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table about device manufacture information."
::= { h3cEntityExtManu 1 }
h3cEntityExtManuEntry OBJECT-TYPE
SYNTAX H3cEntityExtManuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The device manufacture information about a particular physical
entity."
INDEX { h3cEntityExtManuPhysicalIndex }
::= { h3cEntityExtManuTable 1 }
H3cEntityExtManuEntry ::= SEQUENCE {
h3cEntityExtManuPhysicalIndex
Integer32,
h3cEntityExtManuSerialNum
SnmpAdminString,
h3cEntityExtManuBuildInfo
SnmpAdminString,
h3cEntityExtManuBOM
SnmpAdminString,
h3cEntityExtMacAddressCount
Unsigned32
}
h3cEntityExtManuPhysicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of h3cEntityExtManuTable.
This index is identical to entPhysicalIndex in ENTITY-MIB."
::= { h3cEntityExtManuEntry 1 }
h3cEntityExtManuSerialNum OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Manufacture serial number.
The manufacture serial number of the entity such as chassis,
module, and so on. It is got from the device when manufacturing.
For low level box-device, the manufacture serial number is the
device-number of System Control Board(SCB for short), it is written
into the SCB directly; for middle level or high level frame-device,
the manufacture serial number is the device-numbers of SCB and
Service Board, because the SCB, Service Board and chassis are
separate to sale and the device-number of chassis can not be
written into board."
::= { h3cEntityExtManuEntry 2 }
h3cEntityExtManuBuildInfo OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device version information.
The device version information of the entity such as chassis,
module, and so on. It consists of software version information
and hardware version information."
::= { h3cEntityExtManuEntry 3 }
h3cEntityExtManuBOM OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device BOM code.
The device BOM code of the entity such as chassis, module, and so
on. It is the component code of ERP system, which can be
disassembled from device-number."
::= { h3cEntityExtManuEntry 4 }
h3cEntityExtMacAddressCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address count.
The count of MAC addresses of the entity, such as chassis, module,
or port, and so on."
::= { h3cEntityExtManuEntry 5 }
h3cEntityExtPower OBJECT IDENTIFIER ::= { h3cEntityExtObjects 3 }
h3cEntityExtPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cEntityExtPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the power information of all the physical
entity on the device, such as the fans, the subcards, the boards,
etc."
::= { h3cEntityExtPower 1 }
h3cEntityExtPowerEntry OBJECT-TYPE
SYNTAX H3cEntityExtPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entity power information about a particular physical entity."
INDEX { h3cEntityExtPowerPhysicalIndex }
::= { h3cEntityExtPowerTable 1 }
H3cEntityExtPowerEntry ::= SEQUENCE {
h3cEntityExtPowerPhysicalIndex
Integer32,
h3cEntityExtNominalPower
Gauge32,
h3cEntityExtCurrentPower
Gauge32,
h3cEntityExtAveragePower
Integer32,
h3cEntityExtPeakPower
Integer32
}
h3cEntityExtPowerPhysicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of h3cEntityExtPowerTable.
This index is identical to entPhysicalIndex in ENTITY-MIB."
::= { h3cEntityExtPowerEntry 1 }
h3cEntityExtNominalPower OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal power of the entity expressed in milliWatts."
::= { h3cEntityExtPowerEntry 2 }
h3cEntityExtCurrentPower OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured usage power of the entity expressed in milliWatts."
::= { h3cEntityExtPowerEntry 3 }
h3cEntityExtAveragePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The average power consumed by the entity expressed in milliWatts.
Writing a value of zero to this object resets its value to zero.
Writing any other value to this object has no effect on its value
and an error is returned."
::= { h3cEntityExtPowerEntry 4 }
h3cEntityExtPeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The peak power consumed by the entity expressed in milliWatts.
Writing a value of zero to this object resets its value to zero.
Writing any other value to this object has no effect on its value
and an error is returned."
::= { h3cEntityExtPowerEntry 5 }
-- Process Table
h3cProcessObjects OBJECT IDENTIFIER ::= { h3cEntityExtObjects 4 }
h3cProcessTable OBJECT-TYPE
SYNTAX SEQUENCE OF H3cProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Table describes the information about a particular process,
namely a task."
::= { h3cProcessObjects 1 }
h3cProcessEntry OBJECT-TYPE
SYNTAX H3cProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information about a particular process, namely a task."
INDEX { h3cProcessID }
::= { h3cProcessTable 1 }
H3cProcessEntry ::= SEQUENCE {
h3cProcessID Unsigned32,
h3cProcessName DisplayString,
h3cProcessUtil5Min Unsigned32
}
h3cProcessID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the identifier of process, namely task ID
in system."
::= { h3cProcessEntry 1 }
h3cProcessName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the process name."
::= { h3cProcessEntry 2 }
h3cProcessUtil5Min OBJECT-TYPE
SYNTAX Unsigned32(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a general idea of how busy a process caused
the processor to be over a 5 minute period. The ratio is calculated
by the overall CPU usage caused by the process."
::= { h3cProcessEntry 3 }
-- End
h3cEntityExtTraps OBJECT IDENTIFIER ::= { h3cEntityExtend 2 }
h3cEntityExtTrapsPrefix OBJECT IDENTIFIER ::= { h3cEntityExtTraps 0 }
h3cEntityExtTrapsInfor OBJECT IDENTIFIER ::= { h3cEntityExtTraps 1 }
h3cEntityExtTemperatureThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtTemperature,
h3cEntityExtTemperatureThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtTemperatureThresholdNotification
indicates the temperature exceeded the threshold.
In this condition, user should check the status and the
environment of the entity, sometimes it happens because
of the failure of air-condition."
::= { h3cEntityExtTrapsPrefix 1 }
h3cEntityExtVoltageLowThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtVoltage,
h3cEntityExtVoltageLowThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtVoltageLowThresholdNotification indicates
the voltage is lower than the threshold.
If the voltage is lower too much than the entity needs,
the entity will halt."
::= { h3cEntityExtTrapsPrefix 2 }
h3cEntityExtVoltageHighThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtVoltage,
h3cEntityExtVoltageHighThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtVoltageHighThresholdNotification indicates
the voltage is higher than the threshold.
If the voltage is higher too much than the entity needs,
The entity may be damaged by the high voltage."
::= { h3cEntityExtTrapsPrefix 3 }
h3cEntityExtCpuUsageThresholdNotfication NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtCpuUsage,
h3cEntityExtCpuUsageThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight,
h3cEntityExtCpuUsageRecoverThreshold,
h3cEntityExtFirstTrapTime
}
STATUS current
DESCRIPTION
"The h3cEntityExtCpuUsageThresholdNotfication indicates
the entity is overloaded."
::= { h3cEntityExtTrapsPrefix 4 }
h3cEntityExtMemUsageThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtMemUsage,
h3cEntityExtMemUsageThreshold,
h3cEntityExtMemSize,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight,
h3cEntityExtFirstTrapTime
}
STATUS current
DESCRIPTION
"The h3cEntityExtMemUsageThresholdNotification indicates
the entity is overloaded."
::= { h3cEntityExtTrapsPrefix 5 }
h3cEntityExtOperEnabled NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates the entity is operable at present."
::= { h3cEntityExtTrapsPrefix 6 }
h3cEntityExtOperDisabled NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The trap indicates the entity is not operable at present."
::= { h3cEntityExtTrapsPrefix 7 }
h3cEntityExtCriticalTemperatureThresholdNotification NOTIFICATION-TYPE
OBJECTS {
h3cEntityExtPhysicalIndex,
h3cEntityExtTemperature,
h3cEntityExtCriticalTemperatureThreshold,
h3cEntityExtAdminStatus,
h3cEntityExtAlarmLight
}
STATUS current
DESCRIPTION
"The h3cEntityExtCriticalTemperatureThresholdNotification
indicates the temperature exceeds the critical temperature.
In this condition, user should check the status and the