Watermain Adaptive Threshold provides quick leak detection without using impeller

Notifications You must be signed in to change notification settings

Bobbo117/Watermain-Adaptive-Threshold-Implementation

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 

Repository files navigation

Watermain Adaptive Threshold Implementation

  • This project starts with Yang's project at https://github.com/heyitsyang/Whole-House-Water-Leak-Controller .

    • Optional adaptations:
      • Buck converter is replaced by dedicated 5v usb supply wall wart for ESP8266.
      • Standard enclosure is substituted for custom 3D printed electronics enclosure. Install
  • Observations

    • Typical 24 hour pressure profile:

    Day

    • Water pressure varies several psi during the course of a day.
    • Water pressure spikes when water heater is active.
    • Water pressure recovers slowly after demand if there is a pressure regulator.
    • Water flow may not be detected by a static threshhold for slower flow rates or during periods of higher pressure.

How small a leak can we detect without using an impeller?

  • Water flow duration was measured under various conditions (flush, shower, laundry, dishes, etc.)
    • An adaptive threshhold was devised to close the main valve 10 minutes after detecting water flow.
    • Motion detected in the bathrooms or kitchen cause a 20 minute grace period (for showers, proof of consciousness, etc.).
    • Leak vol = leak rate x flow detection time + 10 min x leak rate + water residue after valve closes (approx 20 fl oz = 625 ml)
    • 75 ml/min flow is detected in 80 seconds. Total leak = 75(80/60) + 10(75) + 625 = 1475 ml (=6 cups).
      • 40 ml/min flow is detected in 6 minutes. Total leak = 6(40) +10(40) + 625 = 1265 ml (=5 cups).
      • 24 ml/min flow (22 drips/10 sec) is detected in 11 minutes. Total leak = 11(24) + 10(24) + 625 = 1129 ml (<5 cups).
    • Wide open faucet 5.3 liter/min flow would take 10 minutes to shut down. Leak = 10(5.3)+.625 = 54 liters (14 gal).
      • Therefore use moisture sensors to close valve immediately for larger volumes.

Static pressure test results:

  • Typical nightly results range betwwen -.03 and -.15 psi at my house.

  • Pressure decrease is greater (-. 38 psi +-) if the test is run soon after the water heater has been activated and the pressure tank has peaked and is on the downswing.

  • A 24 ml/min leak causes a 3.44 psi drop during the nightly static pressure test under normal conditions.

Adaptive Threshhold Theory of Operation

  • The adaptive threshhold is based on a "leaky peak detector".
    • Leaky peak - If pressure (P) rises above the peak value, the calculated peak pressure is set equal P.

      • The peak pressure stays constant for the next 10 minutes unless P exceeds it before then.
      • After 10 minutes, the peak is reduced .25 psi if it doesn't go less than P.
      • If P rate of decrease exceeds .25psi/10 min, the calculated peak pressure decreases at a slower rate. Hence, the term leaky peak.
    • Threshhold (T) - The threshhold that defines flow is set at 1 psi below the most recent calculated leaky peak pressure.

    • Flow - When P goes below the threshhold, the 10 minute flow timer begins. After 10 minutes, the valve is closed.

    • Motion Sensors reset the flow timer when motion is detected.

    • There is a similar mechanism to determine the threshhold when the flow stops and the pressure rises again.

    • Examples:

      • The peak and threshhold (T) are recalculated each time the pressure increases above the prior peak.

        Increase

      • The following plot shows the pressure decreasing at a rate of .125 psi/10 min; the peak is reduced .25 psi / 10 min until the two meet.

      • The plots above and below demonstrate an example of the threshold tracking the normal ebb and flow of psi without tripping the flow threshld.

        Decrease

      • Adaptive Threshold operation through two demand cycles:

      • We see that at 8:11 and 8:27 when pressure drops below threshold (flow begins) the threshold flips to above the psi to define when flow stops.

      • At around 8:14 and 8:33 the psi goes above the threshold, (flow stops), and the threshhold once again tracks below the newest max psi.

      Adaptive2

System Operation

  • Based on appliance signatures, a 10 minute flow causes the valve to shut down unless the following conditions exist:
    • Motion is detected in the bathroom or kitchens, causing a 20 minute standby period.
    • The manual override switch has been actuated.
    • Detection of moisture by external sensors cause immediate valve closure.
    • Monitor daily leakage test and graphical representation to catch other issues.

Flow Duration Study

  • Overnight activity followed by shower at 6 am.
    • Note visual sign of failing toilet seal, which was seen before heard:

Toilet Flush

  • This is a great visual tool to monitor the water system. That seal is getting worse! Still can not hear it to identify it.

Shower

  • Wash Machine flow and dishwasher signatures indicate max flow duration is only a few minutes.
    • Laundry:

LaundrySignature

- Dishwasher:

Dishwasher

  • Morning routine including shower:

Adaptive

Hardware

  • PIR motion sensors with optional temperature/humidity report to Home Assistant, causing a 20 minute standby.
  • Be sure to use a 100nf decoupling capacitor across temp sensor Vcc and Gnd to prevent spurious PIR hits.
  • Use most any ESPxyz here. Standardizing with ESP32 keeps my life simple, if inelegant.
  • Add a white Ailkin USB power adapter and some velcro tape to the assembly and plug it in.
    • The blue LED is easily visible when motion is detected.
  • Software for the PIR sensor is at https://github.com/Bobbo117/Cellular-IoT-Monitor/blob/main/src/AmbientAP/AmbientAP.ino .
    • Enable HA so that it will communicate with home assistant or an alternative destnation.
    • Use CASA_1 ID 4 (kitchen), 5 (bathroom), and 6 (bathroom2) for up to three PIR sensors.
    • These IDs will send the topics kithcen/pir, bathroom/pir, and bathroom2/pir respectively.

PIR_Disassembled

PIR_Assembled

Software

  • Adjustments to the original Watermain software are minimal:
    • New variable definitions and mqtt topics are appended at the beginning.
    • New command topics are appended to the mqtt callback function.
    • New processing is appended at the end of the loop() function.
    • Two new threshold functions are appended at the end of the code after the loop function.

Tips, Tricks, and Traps

  • If you take a long shower (> 10 minutes), verify that the bathroom motion sensor sees you! Look for the blue light.
  • For showers longer than 20 minutes, don't forget to wave at the motion sensor once in a while.
  • Activate the Manual Override switch in the HA screen for the powerwash vendor or other vendors using water.
  • Keep an eye on the motion sensors. If one stops working, you could be in for a surprise in the shower at about 10 minutes.

Results

  • This system has operated 6 months with no unanticipated shutoffs.
  • Very slow leak rates may not close the valve, especially if the pressure happens to be on the up cycle.
    • In this case, the nightly Static Pressure Test gives an abnormally high reading that should be followed up.

Home Assistant Screens

  • These screens along with Yang's will help you navigate your way through the software:

Increase

1

2

4

Conclusions

  • While this adaptive threshold mechanism is not as sensitive as an impeller, it provides an added layer of protection without the expense.

  • This is a great project for those who want to become as one with their plumbing system while simultaneously protecting against one of the more frequent and expensive insurance claims.