Skip to content

Tasmota Berry Script for Smart Meter TD-3511 used in upper austria (Netz OÖ)

License

Notifications You must be signed in to change notification settings

Charly-2/Tasmota-TD3511-MBus

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

26 Commits
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Tasmota-TD3511-MBus

Tasmota Berry Script for Smart Meter TD-3511 used in Upper Austria (Netz OÖ)

Description

This Berry Script can be used with Tasmota https://tasmota.github.io/docs/ on ESP32-Modules. It can read Siemens Smart Meters of Type TD-3511 which are used in Uppper Austria by Netz OÖ / Energie AG. The script acts as M-Bus client and reads the values provided by the smart meters every second. More than one smart meter can be attached to an ESP32 and read out.

I didn't find a way to use the https://tasmota.github.io/docs/Smart-Meter-Interface/ to act as M-Bus-Client, so i tried Berry Scripting...

The known Tasmota-Scripts for TD-3511 can read the Netz-OÖ-smart meters only with 300Bd and update the values only every 5 minutes. See https://magnatdebonblog.wordpress.com/offtopic-smart-meter-der-energie-ag-mit-esp-32-auslesen-und-per-mqtt-weitergeben/

There are ready-to-use M-Bus-IR-readers available e.g. here (not sold by me!) : https://github.com/mgerhard74/amis_smartmeter_reader

Specification of AMIS Smart Meter M-Bus interface: https://www.netzooe.at/2021-11-05-spezifikation-ks-amis.pdf?ch=ttzaxj8g&:hp=3;2;de

Other FAQs from Netz-OÖ: https://www.netzooe.at/themen/information/smart-meter/faq

Requirements / Setup

Compile Tasmota with Berry and Crypto-Support

You need to compile a Tasmota version with this minimal settings - see https://tasmota.github.io/docs/Compile-your-build/

// Berry cripting and SML for SmartMeters
#ifndef USE_SCRIPT
  #define USE_SCRIPT
#endif
#ifndef USE_SML_M
  #define USE_SML_M
#endif
#ifdef USE_RULES
  #undef USE_RULES
#endif
#ifndef USE_TLS
  #define USE_TLS
#endif
#ifndef USE_BERRY_DEBUG
  #define USE_BERRY_DEBUG
#endif
#ifndef USE_BERRY_CRYPTO_AES_CBC
  #define USE_BERRY_CRYPTO_AES_CBC
#endif

Serial IR Smart-meter Reader

For every smart meter you need a IR-Serial-Transceiver connected to ESP32 Serial Pins (you need RX and TX)

Like this one: https://www.amazon.de/Hichi/dp/B0BPMVX4VW?th=1

Upload Berry Script-Files

Upload all *.be Files via the Tasmota-Web-Interface to the ESP32 (Tools -> Manage File System)

Configure Script

Edit the file td3511_setup.be and change RX/TX-Pins and AES-KEY and ID for every smart meter you need. You can edit in Tasmota with the "Edit-Icon" in Manage Filesystem.

The Section for Initializing one Smart-Meter looks like this:

# Zähler Haushalt
td3511_HH=TD3511MBUS(46,45,bytes('11C5151F9CB6EFD13E411B815CD62769'), "Z1")
tasmota.add_driver(td3511_HH)
print("Driver td3511_HH:TD3511MBUS initialized")

Configure Teleperiod

The frequency for sending MQTT-Messages must be adjusted in Tasmota:

Configuration->Configure Logging-> Telemetry period (e.g. 10seconds)

Reboot the ESP32

Reboot from Tasmota Main-Menu and wait....

Usage

After correct initialisation the smart meter starts sending packets with data.

Main View

You can see the values in the Tasmota WEB-UserInterface Main-View:

Berry Console

The Berry Console gives more debug output

MQTT

At the moment only some values are sent via MQTT for every smart meter.

Disclaimer

This software is in a very pre-beta-state! I can't be held responsible for any problems by using this software!

Thanks

Thanks to @mgerhard74. His software was a excelent starting point for this Tasmota-Scipt.