89 changes: 89 additions & 0 deletions _docs/alarm.alarm_rule.rst
Original file line number Diff line number Diff line change
@@ -1,6 +1,95 @@
Alarm Rule
============

One :class:`.Alarm_Rule` is defined for each :class:`~.alarm.AlarmType` in :data:`.ALARM_RULES`.

An alarm rule defines:

* The conditions for raising different severities of an alarm
* The dependencies between set values and alarm thresholds
* The behavior of the alarm, specifically whether it is :attr:`~.Alarm_Rule.latch` ed.

Example
----------

As an example, we'll define a ``LOW_PRESSURE`` alarm with escalating severity. A ``LOW`` severity alarm
will be raised when measured ``PIP`` falls 10% below set ``PIP``, which will escalate to a
``MEDIUM`` severity alarm if measured ``PIP`` falls 15% below set ``PIP`` **and** the ``LOW`` severity
alarm has been active for at least two breath cycles.

First we define the name and behavior of the alarm::

Alarm_Rule(
name = AlarmType.LOW_PRESSURE,
latch = False,

In this case, ``latch == False`` means that the alarm will disappear (or be downgraded in severity)
whenever the conditions for that alarm are no longer met. If ``latch == True``, an alarm requires manual dismissal before
it is downgraded or disappears.

Next we'll define a tuple of :class:`.Condition` objects for ``LOW`` and ``MEDIUM`` severity objects.

Starting with the ``LOW`` severity alarm::

conditions = (
(
AlarmSeverity.LOW,
condition.ValueCondition(
value_name=ValueName.PIP,
limit=VALUES[ValueName.PIP]['safe_range'][0],
mode='min',
depends={
'value_name': ValueName.PIP,
'value_attr': 'value',
'condition_attr': 'limit',
'transform': lambda x : x-(x*0.10)
})
),
# ... continued in next block

Each condition is a tuple of an (:class:`.AlarmSeverity`, :class:`.Condition`). In this case,
we use a :class:`.ValueCondition` which tests whether a value is above or below a set ``'max'`` or ``'min'``, respectively.
For the low severity ``LOW_PRESSURE`` alarm, we test if ``ValueName.PIP`` is below (``mode='min'``) some ``limit``, which
is initialized as the low-end of ``PIP``'s safe range.

We also define a condition for updating the ``'limit'`` of the condition (``'condition_attr' : 'limit'``), from the
:attr:`.ControlSetting.value`` field whenever ``PIP`` is updated. Specifically, we set the ``limit`` to be 10% less than the
set ``PIP`` value by 10% with a lambda function (``lambda x : x-(x*0.10)``).

Next, we define the ``MEDIUM`` severity alarm condition::

(
AlarmSeverity.MEDIUM,
condition.ValueCondition(
value_name=ValueName.PIP,
limit=VALUES[ValueName.PIP]['safe_range'][0],
mode='min'
depends={
'value_name': ValueName.PIP,
'value_attr': 'value',
'condition_attr': 'limit',
'transform': lambda x: x - (x * 0.15)
},
) + \
condition.CycleAlarmSeverityCondition(
alarm_type = AlarmType.LOW_PRESSURE,
severity = AlarmSeverity.LOW,
n_cycles = 2
))

The first ``ValueCondition`` is the same as in the ``LOW`` alarm severity condition, except that it is
set 15% below ``PIP``.

A second :class:`.CycleAlarmSeverityCondition` has been added (with ``\+``) to the :class:`.ValueCondition`
When conditions are added together, they will only return ``True`` (ie. trigger an alarm) if all of the conditions are met.
This condition checks that the ``LOW_PRESSURE`` alarm has been active at a ``LOW`` severity for at least two cycles.

For the full source code of this example,


Module Documentation
--------------------

.. automodule:: pvp.alarm.rule
:members:
:undoc-members:
Expand Down
73 changes: 0 additions & 73 deletions _docs/alarm.rst
Original file line number Diff line number Diff line change
Expand Up @@ -20,79 +20,6 @@ continuously fed :class:`~.message.SensorValues` objects during :meth:`.PVP_Gui.
:meth:`.PVP_Gui.handle_alarm` method. The alarm manager also updates alarm thresholds set as :attr:`.Condition.depends`
when control parameters are set (eg. updates the ``HIGH_PRESSURE`` alarm to be triggered 15% above some set ``PIP`` ).

Alarm Rule Example
~~~~~~~~~~~~~~~~~~~

One :class:`.Alarm_Rule` is defined for each :class:`~.alarm.AlarmType` in :data:`.ALARM_RULES`.

An alarm rule defines:

* The conditions for raising different severities of an alarm
* The dependencies between set values and alarm thresholds
* The behavior of the alarm, specifically whether it is :attr:`~.Alarm_Rule.latch` ed.

As an example, we'll define a ``LOW_PRESSURE`` alarm with escalating severity. First we define the name and
behavior of the alarm::

Alarm_Rule(
name = AlarmType.LOW_PRESSURE,
latch = False,

In this case, ``latch == False`` means that the alarm will disappear (or be downgraded in severity)
whenever the conditions for that alarm are no longer met. If ``latch == True``, an alarm requires manual dismissal before
it is downgraded or disappears.

Next we'll define a tuple of :class:`.Condition` objects for ``LOW`` and ``MEDIUM`` severity objects.

Starting with the ``LOW`` severity alarm::

conditions = (
(
AlarmSeverity.LOW,
condition.ValueCondition(
value_name=ValueName.PIP,
limit=VALUES[ValueName.PIP]['safe_range'][0],
mode='min',
depends={
'value_name': ValueName.PIP,
'value_attr': 'value',
'condition_attr': 'limit',
'transform': lambda x : x-(x*0.10)
})
),
# ... continued in next block

Each condition is a tuple of an ``(:class:`.AlarmSeverity`, :class:`.Condition`)``. In this case,
we use a :class:`.ValueCondition` which tests whether a value is above or below a set ``'max'`` or ``'min'``, respectively.
For the low severity ``LOW_PRESSURE`` alarm, we test if ``ValueName.PIP`` is below (``mode='min'``) some ``limit``, which
is initialized as the low-end of ``PIP``'s safe range.

We also define a condition for updating the ``'limit'`` of the condition (``'condition_attr' : 'limit'``), from the
:attr:`.ControlSetting.value`` field whenever ``PIP`` is updated. Specifically, we set the ``limit`` to be 10% less than the
set ``PIP`` value by 10% with a lambda function (``lambda x : x-(x*0.10)``).

Next, we define the ``MEDIUM`` severity alarm condition::


(
AlarmSeverity.MEDIUM,
condition.ValueCondition(
value_name=ValueName.PIP,
limit=VALUES[ValueName.PIP]['safe_range'][0]- \
VALUES[ValueName.PIP]['safe_range'][0]*0.15,
depends={
'value_name': ValueName.PIP,
'value_attr': 'value',
'condition_attr': 'limit',
'transform': lambda x: x - (x * 0.15)
},
mode='min'
) + \
condition.CycleAlarmSeverityCondition(
alarm_type = AlarmType.LOW_PRESSURE,
severity = AlarmSeverity.LOW,
n_cycles = 2
))


Main Alarm Module
Expand Down
3 changes: 3 additions & 0 deletions pvp/alarm/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -247,4 +247,7 @@ class AlarmSeverity(IntEnum):
)
),
})
"""
Definitions of all :class:`.Alarm_Rule` s used by the :class:`.Alarm_Manager`
"""

0 comments on commit bc2caea

Please sign in to comment.