AlexanderSemenyak commented Jun 17, 2023

DewCurveDeltaT - do not need convert from/to SI in FormPhEnv

Expected behavior
Delta T without convert from/to SI

Screenshots
image

Desktop (please complete the following information):

  • OS: Windows
  • Version 8.4.7
@AlexanderSemenyak AlexanderSemenyak added the bug Something isn't working label Jun 17, 2023
@AlexanderSemenyak AlexanderSemenyak changed the title [Bug] DewCurveDeltaT - do not need convert from/to SI in FormPhEnv [Bug] Jun 17, 2023
@AlexanderSemenyak
Copy link
Contributor Author

E.g. convert delta 1 C to SI => 274 K, but need stay 1 K

@DanWBR
Copy link
Owner

DanWBR commented Jun 26, 2023

@AlexanderSemenyak it does need conversion because 1 delta C/K is different from 1 delta F/R

I checked and the conversion is ok, showing up as 2.5 C when converting from 2.5 K

@DanWBR
Copy link
Owner

DanWBR commented Jun 26, 2023

the error was somewhere else! thanks