Expand Up @@ -203,6 +203,7 @@ Columns
":code:`rhu1_45F_to_50F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`45 \leq T_{out} < 50`"
":code:`rhu1_50F_to_55F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq T_{out} < 55`"
":code:`rhu1_55F_to_60F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`55 \leq T_{out} < 60`"
":code:`rhu1_30F_to_45F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq T_{out} < 45`"
":code:`rhu1_00F_to_05F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{aux}}{T_{out}} < 5`"
":code:`rhu1_05F_to_10F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`5 \leq \frac{T_{aux}}{T_{out}} < 10`"
":code:`rhu1_10F_to_15F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{aux}}{T_{out}} < 15`"
Expand All @@ -214,7 +215,8 @@ Columns
":code:`rhu1_40F_to_45F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`40 \leq \frac{T_{aux}}{T_{out}}< 45`"
":code:`rhu1_45F_to_50F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`45 \leq \frac{T_{aux}}{T_{out}} < 50`"
":code:`rhu1_50F_to_55F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{aux}}{T_{out}} < 55`"
":code:`rhu1_55F_to_60F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{aux}}{T_{out}} < 5`"
":code:`rhu1_55F_to_60F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`55 \leq \frac{T_{aux}}{T_{out}} < 60`"
":code:`rhu1_30F_to_45F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{aux}}{T_{out}} < 45`"
":code:`rhu1_00F_to_05F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{emerg}}{T_{out}} < 5`"
":code:`rhu1_05F_to_10F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`5 \leq \frac{T_{emerg}}{T_{out}} < 10`"
":code:`rhu1_10F_to_15F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{emerg}}{T_{out}} < 15`"
Expand All @@ -227,6 +229,7 @@ Columns
":code:`rhu1_45F_to_50F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`45 \leq \frac{T_{emerg}}{T_{out}} < 50`"
":code:`rhu1_50F_to_55F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{emerg}}{T_{out}} < 55`"
":code:`rhu1_55F_to_60F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`55 \leq \frac{T_{emerg}}{T_{out}} < 60`"
":code:`rhu1_30F_to_45F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{emerg}}{T_{out}} < 45`"
":code:`rhu1_00F_to_05F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{comp}}{T_{out}} < 5`"
":code:`rhu1_05F_to_10F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`5 \leq \frac{T_{comp}}{T_{out}} < 10`"
":code:`rhu1_10F_to_15F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{comp}}{T_{out}} < 15`"
Expand All @@ -239,30 +242,7 @@ Columns
":code:`rhu1_45F_to_50F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`45 \leq \frac{T_{comp}}{T_{out}} < 50`"
":code:`rhu1_50F_to_55F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{comp}}{T_{out}} < 55`"
":code:`rhu1_55F_to_60F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`55 \leq \frac{T_{comp}}{T_{out}} < 60`"
":code:`rhu1_less10F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq T_{out} < 10`"
":code:`rhu1_10F_to_20F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`10 \leq T_{out} < 20`"
":code:`rhu1_20F_to_30F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`20 \leq T_{out} < 30`"
":code:`rhu1_30F_to_40F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq T_{out} < 40`"
":code:`rhu1_40F_to_50F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`40 \leq T_{out} < 50`"
":code:`rhu1_50F_to_60F`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq T_{out} < 60`"
":code:`rhu1_less10F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{aux}}{T_{out}} < 10`"
":code:`rhu1_10F_to_20F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{aux}}{T_{out}} < 20`"
":code:`rhu1_20F_to_30F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`20 \leq \frac{T_{aux}}{T_{out}} < 30`"
":code:`rhu1_30F_to_40F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{aux}}{T_{out}} < 40`"
":code:`rhu1_40F_to_50F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`40 \leq \frac{T_{aux}}{T_{out}} < 50`"
":code:`rhu1_50F_to_60F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{aux}}{T_{out}} < 60`"
":code:`rhu1_less10F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{emerg}}{T_{out}} < 10`"
":code:`rhu1_10F_to_20F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{emerg}}{T_{out}} < 20`"
":code:`rhu1_20F_to_30F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`20 \leq \frac{T_{emerg}}{T_{out}} < 30`"
":code:`rhu1_30F_to_40F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{emerg}}{T_{out}} < 40`"
":code:`rhu1_40F_to_50F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`40 \leq \frac{T_{emerg}}{T_{out}} < 50`"
":code:`rhu1_50F_to_60F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{emerg}}{T_{out}} < 60`"
":code:`rhu1_less10F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{comp}}{T_{out}} < 10`"
":code:`rhu1_10F_to_20F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{comp}}{T_{out}} < 20`"
":code:`rhu1_20F_to_30F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`20 \leq \frac{T_{comp}}{T_{out}} < 30`"
":code:`rhu1_30F_to_40F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{comp}}{T_{out}} < 40`"
":code:`rhu1_40F_to_50F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`40 \leq \frac{T_{comp}}{T_{out}} < 50`"
":code:`rhu1_50F_to_60F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{comp}}{T_{out}} < 60`"
":code:`rhu1_30F_to_45F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","Resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{comp}}{T_{out}} < 45`"
":code:`rhu2_aux_duty_cycle`","float","minutes","Resistance heat utilization auxiliary duty cycle"
":code:`rhu2_emg_duty_cycle`","float","minutes","Resistance heat utilization emergency duty cycle"
":code:`rhu2_compressor_duty_cycle`","float","minutes","Resistance heat utilization compressor duty cycle"
Expand All @@ -278,6 +258,7 @@ Columns
":code:`rhu2_45F_to_50F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`45 \leq T_{out} < 50`"
":code:`rhu2_50F_to_55F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`50 \leq T_{out} < 55`"
":code:`rhu2_55F_to_60F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`55 \leq T_{out} < 60`"
":code:`rhu2_30F_to_45F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq T_{out} < 45`"
":code:`rhu2_00F_to_05F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{aux}}{T_{out}} < 5`"
":code:`rhu2_05F_to_10F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`5 \leq \frac{T_{aux}}{T_{out}} < 10`"
":code:`rhu2_10F_to_15F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{aux}}{T_{out}} < 15`"
Expand All @@ -290,6 +271,7 @@ Columns
":code:`rhu2_45F_to_50F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`45 \leq \frac{T_{aux}}{T_{out}} < 50`"
":code:`rhu2_50F_to_55F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{aux}}{T_{out}} < 55`"
":code:`rhu2_55F_to_60F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{aux}}{T_{out}} < 5`"
":code:`rhu2_30F_to_45F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{aux}}{T_{out}} < 45`"
":code:`rhu2_00F_to_05F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{emerg}}{T_{out}} < 5`"
":code:`rhu2_05F_to_10F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`5 \leq \frac{T_{emerg}}{T_{out}} < 10`"
":code:`rhu2_10F_to_15F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{emerg}}{T_{out}} < 15`"
Expand All @@ -302,6 +284,7 @@ Columns
":code:`rhu2_45F_to_50F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`45 \leq \frac{T_{emerg}}{T_{out}} < 50`"
":code:`rhu2_50F_to_55F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{emerg}}{T_{out}} < 55`"
":code:`rhu2_55F_to_60F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`55 \leq \frac{T_{emerg}}{T_{out}} < 60`"
":code:`rhu2_30F_to_45F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{emerg}}{T_{out}} < 45`"
":code:`rhu2_00F_to_05F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{comp}}{T_{out}} < 5`"
":code:`rhu2_05F_to_10F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`5 \leq \frac{T_{comp}}{T_{out}} < 10`"
":code:`rhu2_10F_to_15F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{comp}}{T_{out}} < 15`"
Expand All @@ -314,32 +297,6 @@ Columns
":code:`rhu2_45F_to_50F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`45 \leq \frac{T_{comp}}{T_{out}} < 50`"
":code:`rhu2_50F_to_55F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{comp}}{T_{out}} < 55`"
":code:`rhu2_55F_to_60F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`55 \leq \frac{T_{comp}}{T_{out}} < 60`"
":code:`rhu2_less10F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq T_{out} < 10`"
":code:`rhu2_10F_to_20F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`10 \leq T_{out} < 20`"
":code:`rhu2_20F_to_30F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`20 \leq T_{out} < 30`"
":code:`rhu2_30F_to_40F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq T_{out} < 40`"
":code:`rhu2_40F_to_50F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`40 \leq T_{out} < 50`"
":code:`rhu2_30F_to_45F`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq T_{out} < 45`"
":code:`rhu2_less10F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{aux}}{T_{out}} < 10`"
":code:`rhu2_10F_to_20F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{aux}}{T_{out}} < 20`"
":code:`rhu2_20F_to_30F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`20 \leq \frac{T_{aux}}{T_{out}} < 30`"
":code:`rhu2_30F_to_40F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{aux}}{T_{out}} < 40`"
":code:`rhu2_40F_to_50F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`40 \leq \frac{T_{aux}}{T_{out}} < 50`"
":code:`rhu2_50F_to_60F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{aux}}{T_{out}} < 60`"
":code:`rhu2_30F_to_45F_aux_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{aux}}{T_{out}} < 45`"
":code:`rhu2_less10F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{emerg}}{T_{out}} < 10`"
":code:`rhu2_10F_to_20F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{emerg}}{T_{out}} < 20`"
":code:`rhu2_20F_to_30F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`20 \leq \frac{T_{emerg}}{T_{out}} < 30`"
":code:`rhu2_30F_to_40F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{emerg}}{T_{out}} < 40`"
":code:`rhu2_40F_to_50F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`40 \leq \frac{T_{emerg}}{T_{out}} < 50`"
":code:`rhu2_50F_to_60F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{emerg}}{T_{out}} < 60`"
":code:`rhu2_30F_to_45F_emg_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{emerg}}{T_{out}} < 45`"
":code:`rhu2_less10F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`0 \leq \frac{T_{comp}}{T_{out}} < 10`"
":code:`rhu2_10F_to_20F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`10 \leq \frac{T_{comp}}{T_{out}} < 20`"
":code:`rhu2_20F_to_30F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`20 \leq \frac{T_{comp}}{T_{out}} < 30`"
":code:`rhu2_30F_to_40F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{comp}}{T_{out}} < 40`"
":code:`rhu2_40F_to_50F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`40 \leq \frac{T_{comp}}{T_{out}} < 50`"
":code:`rhu2_50F_to_60F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`50 \leq \frac{T_{comp}}{T_{out}} < 60`"
":code:`rhu2_30F_to_45F_compressor_duty_cycle`","decmial","0.0=0%, 1.0=100%","RHU2 filtered resistance heat utilization for hourly temperature bin :math:`30 \leq \frac{T_{comp}}{T_{out}} < 45`"


Expand Down
15 changes: 14 additions & 1 deletion docs/tutorial.rst
Original file line number Diff line number Diff line change
Expand Up @@ -328,10 +328,11 @@ data set.
product_id = "INSERT ALPHANUMERIC PRODUCT ID HERE"
stats_filepath = os.path.join(data_dir, "thermostat_example_stats.csv")
# Need to save the stats to pass to the certification_to_csv exporter for certification data
stats_df = summary_statistics_to_csv(stats, stats_filepath, product_id)
# or with advanced filter outputs
# stats_advanced_filepath = os.path.join(data_dir
# stats_advanced_filepath = os.path.join(data_dir,
# "thermostat_example_stats_advanced.csv")
# stats_advanced_df = summary_statistics_to_csv(stats_advanced,
# stats_advanced_filepath,
Expand All @@ -342,6 +343,18 @@ grouped by climate zone. Heavier weights are applied to results in climate
zones which, regionally, tend to have longer runtimes. Weightings used are
available :download:`for download <../thermostat/resources/NationalAverageClimateZoneWeightings.csv>`.

Certification File
------------------

Once you have saved the summary statistics you may then create the
certification file, which is also submitted to the EPA.

.. code-block:: python
certification_filepath = os.path.join(data_dir,
"thermostat_example_certification.csv")
certification_to_csv(stats_df, certification_filepath)