ESP32C++ code to connect and test connexion to JSY-MK-194 power data mesurement module

France - Bordeaux 7 Mars 2024

I use this module to manage and monitor the solar production of the photovoltaic panels and the consumption of the house to optimize consumption from the grid by automating electrical equipment.

Module JSY-MK-194

I created this code because I couldn't find anything on the Internet that was reasonably safe and efficient, even with an AI (until now...).

This code adds CRC check, correct slave number in the answer frame (if you need to connect several Modbus modules) and a frame timeout which allows you to scan as fast as you need without scan delay. see below for shakespeare's langage

Dev ESP32 connecté au module JSY-MK-194R par le port UART2 en utilisant le protocole MODBUS RTU

Au préalable avec une carte de conversion TTL-USB, j'ai utilisé l'émulateur Modbus (Modbus-Tool) pour tester et mettre la vitesse à 19200 bauds

Bordeaux - 06 Mars 2024

Table Modbus 0x48H + offset ci-dessous depuis la doc constructeur JSY_MK_194_Manual_english.pdf du 5/5/2023

  Tension circuit 1      = 3, 4, 5, 6  >> la valeur occupe 4 octets
  Intensité circuit 11   = 7, 8, 9, 10
  Puissnce circuit 1     = 11, 12, 13, 14
  Energie + circuit 1    = 15, 16, 17, 18
  powerfactor C1         = 19, 20, 21, 22
  Energie - circuit 1    = 23, 24, 25, 26
  Sens courant circuit 1 = 27                 >> si = 0x01 > sens negatif;  0x00 > sens positif , la valeur occupe un octet
  Sens courant circuit 2 = 28
  not used = 29, 30
  ....
  circuit 2 : Ajouter 32 a toutes les adresses du circuit 1

connexions - cablâge

  ESP32 <-> JSY-MK-194
  Tension 3.3V --- VCC      
   Rx2 GPIO16  --- Tx       
   Tx2 GPIO17  --- Rx       
     -   GND   --- GND

*/

/* English (... my english !)

Dev ESP32 connected to JSY-MK-194R module withing UART2 port - MODBUS RTU protocol

Fistly with TTL to USB board, I used Modbus emulator to test and directly set de baudrate to 19200 , you can do what you want but don't forget to change in the code accordingly (19200 by default)

Bordeaux - 07 Mars 2024

Modbus table 0x48H + offset below (from JSY_MK_194_Manual_english.pdf 5/5/2023)

  Voltage circuit 1   = 3, 4, 5, 6  >> Value on 4 bytes
  Current circuit 1   = 7, 8, 9, 10
  Power circuit 1     = 11, 12, 13, 14
  PositiveEnergy 1    = 15, 16, 17, 18
  powerfactor C1      = 19, 20, 21, 22
  Energy - circuit 1  = 23, 24, 25, 26
  Direction circuit 1 = 27                 >> if = 0x01 >  negative;  0x00 >  positive , One Byte
  Direction circuit 2 = 28
  not used            = 29, 30
  ....
  circuit 2 : Add 32 to Circuit 1 addresses

Wiring

        ESP32 <-> JSY-MK-194
   Power 3.3V --- VCC
   Rx2 GPIO16  --- Tx
   Tx2 GPIO17  --- Rx