Read time too much when scanner scanned a barcode. #20
Comments
What is the size of your data?If data is large, higher baudrate is better. And async functions may be delayed due to other program. There some para which you can set: Please see https://docs.microsoft.com/en-us/windows/win32/api/winbase/ns-winbase-commtimeouts SerialPort(
String portName, {
// ignore: non_constant_identifier_names
int BaudRate = CBR_115200,
// ignore: non_constant_identifier_names
int Parity = NOPARITY,
// ignore: non_constant_identifier_names
int StopBits = ONESTOPBIT,
// ignore: non_constant_identifier_names
int ByteSize = 8,
// ignore: non_constant_identifier_names
int ReadIntervalTimeout = 10,
// ignore: non_constant_identifier_names
int ReadTotalTimeoutConstant = 1,
// ignore: non_constant_identifier_names
int ReadTotalTimeoutMultiplier = 10,
/// if you want open port when create instance, set [openNow] true
bool openNow = true,
}) And I use I don't know if changing this parameter will solve your problem. But it does take up CPU time. /// look up I/O event and read data using stream
Stream<Uint8List> _lookUpEvent(Duration interval) async* {
int event = 0;
Uint8List data;
PurgeComm(handler!, PURGE_RXCLEAR | PURGE_TXCLEAR);
while (true) {
await Future.delayed(interval);
event = WaitCommEvent(handler!, _dwCommEvent, _over);
if (event != 0) {
ClearCommError(handler!, _errors, _status);
if (_status.ref.cbInQue < _readBytesSize) {
data = await _read(_status.ref.cbInQue);
} else {
data = await _read(_readBytesSize);
}
if (data.isNotEmpty) {
yield data;
}
} else {
if (GetLastError() == ERROR_IO_PENDING) {
/// For Loop
for (int i = 0; i < 500; i++) {
if (WaitForSingleObject(_over.ref.hEvent, 0) == 0) {
ClearCommError(handler!, _errors, _status);
if (_status.ref.cbInQue < _readBytesSize) {
data = await _read(_status.ref.cbInQue);
} else {
data = await _read(_readBytesSize);
}
if (data.isNotEmpty) {
yield data;
}
ResetEvent(_over.ref.hEvent);
break;
}
ResetEvent(_over.ref.hEvent);
await Future.delayed(interval);
}
}
}
}
} |
My barcode data as following: Thank you for attantion. But I found following in the package: SerialPort._internal(
this.portName,
this._portNameUtf16, {
// ignore: non_constant_identifier_names
required int BaudRate,
// ignore: non_constant_identifier_names
required int Parity,
// ignore: non_constant_identifier_names
required int StopBits,
// ignore: non_constant_identifier_names
required int ByteSize,
// ignore: non_constant_identifier_names
required int ReadIntervalTimeout,
// ignore: non_constant_identifier_names
required int ReadTotalTimeoutConstant,
// ignore: non_constant_identifier_names
required int ReadTotalTimeoutMultiplier,
required bool openNow,
}) {
dcb
..ref.BaudRate = BaudRate
..ref.Parity = Parity
..ref.StopBits = StopBits
..ref.ByteSize = ByteSize;
commTimeouts
..ref.ReadIntervalTimeout = 10
..ref.ReadTotalTimeoutMultiplier = 10
..ref.ReadTotalTimeoutConstant = 1;
if (openNow) {
open();
}
} If I set values, it constructs with default values. Or am I thinking wrong? |
@Abduraimbek I test the barcode data with virtual serial port driver. I send data from COM6. Then I can get data immediately in COM5. The delay is about max 10ms. Are you sure that your device has no hardware delay? About parameters: |
Thanks for the reply. I will try with other new scanners. |
I have change code to improve read performance. Now read latency drops. Updates will be released in version |
Thanks for great work.
I have problem with scanning barcode. When I scan a barcode with scanner, readBytesOnListen fires after 1 to 2 seconds. What should I do? Thanks for solution.
The text was updated successfully, but these errors were encountered: