Skip to content

Commit

Permalink
Update Readme.md (#82)
Browse files Browse the repository at this point in the history
  • Loading branch information
FredM67 committed Feb 15, 2024
1 parent 82d84ee commit eac769e
Showing 1 changed file with 5 additions and 5 deletions.
10 changes: 5 additions & 5 deletions Readme.md
Original file line number Diff line number Diff line change
Expand Up @@ -177,7 +177,7 @@ In a balanced situation, you don't need any neutral wire. To switch off the devi

For that, I've "recycled" a peak/off peak 3-phase relay but you can use any 3-phase relay. It doesn't matter on which phase the command coil is connected, but it must be permanent (not through the router).

![Heater with mechanical thermostat](../../img/Heater_mechanical.png)
![Heater with mechanical thermostat](img/Heater_mechanical.png)
*Figure: Wiring diagram*

## Heater with ACI single phase thermostat

Check failure on line 183 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI

Check failure on line 183 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI
Expand All @@ -186,7 +186,7 @@ In this case, it's somehow the same situation as before.
You don't need to buy a 3-phase kit to convert your single phase heater.
The ACI pcb must be connected to a permanent phase. It will then control any 3-phase relay.

Check failure on line 187 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI

Check failure on line 187 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI

![Heater with ACI single phase thermostat](../../img/Heater_ACI_Mono.png)
![Heater with ACI single phase thermostat](img/Heater_ACI_Mono.png)

Check failure on line 189 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI

Check failure on line 189 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI
*Figure: Wiring diagram*

## Heater with ACI 3-phase thermostat (without neutral wire)

Check failure on line 192 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI

Check failure on line 192 in Readme.md

View workflow job for this annotation

GitHub Actions / spellcheck

ACI ==> ACPI
Expand All @@ -205,7 +205,7 @@ The remaining connected phase is the one in the middle of the power connector.

The ACI pcb must be connected to 3 permanent phases.

![Heater with ACI 3-phase thermostat](../../img/Heater_ACI_Tri.png)
![Heater with ACI 3-phase thermostat](img/Heater_ACI_Tri.png)
*Figure: Wiring diagram*

## Alternatives WITHOUT neutral wire
Expand All @@ -230,12 +230,12 @@ In **red**, security switch (see the 'S' on each pole) : all 3 phases are switch

In **green**, only 2 phases are switched off, L2 et L3. ***It is IMPORTANT that the phase L1, not switched by the thermostat, DOES NOT pass through the triac***.

![Mechanical thermostat](../../img/Thermostat.png)
![Mechanical thermostat](img/Thermostat.png)
*Figure: An example of a thermostat*

---

![Heater with mechanical thermostat](../../img/Heater_mechanical-No_neutral.png)
![Heater with mechanical thermostat](img/Heater_mechanical-No_neutral.png)
*Figure: Wiring diagram*

## Support
Expand Down

0 comments on commit eac769e

Please sign in to comment.