We read every piece of feedback, and take your input very seriously.
To see all available qualifiers, see our documentation.
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
I just updated our hamlib package to 4.5.3 in Mageia and also updated to wsjtx-2 6.0 at the same time.
Now klog and wsjtx are broken with my radio at least!
If you want more info please ask and I will create some more logs as usual.
It's strange that freqMainA=14299390 (which is correct) yet:
rig_powerstat is not on = 0 is that logic reversed?
Anyway over to you :)
BTW Happy New Year!
Barry
2023-01-09T15:52:52.732355-0000: rig_get_mode(2534): freqMainA=14299390, modeMainA=USB, widthMainA=2700 2023-01-09T15:52:52.732371-0000: rig_get_mode(2534): freqMainB=7073000, modeMainB=, widthMainB=0 2023-01-09T15:52:52.732388-0000: -1:rig_get_mode: elapsed=38ms 2023-01-09T15:52:52.732403-0000: -1:rig.c(2537):rig_get_mode returning(0) 2023-01-09T15:52:52.732419-0000: -2:rig.c(1370):rig_open returning(0) Opened rig model 2003, 'TS-450S' 2023-01-09T15:52:52.732448-0000: Backend version: 20221230.0, Status: Stable 2023-01-09T15:52:52.732462-0000: rigctl_parse: called, interactive=1
Rig command: f 2023-01-09T15:52:57.326794-0000: rigctl_parse: cmd=f(66) handle=0 2023-01-09T15:52:57.326824-0000: rigctl_parse: vfo_opt=0 2023-01-09T15:52:57.326858-0000: -2:rig.c(6023):rig_get_powerstat entered 2023-01-09T15:52:57.326875-0000: rig.c(6043) trace 2023-01-09T15:52:57.326889-0000: -1:kenwood.c(4877):kenwood_get_powerstat entered 2023-01-09T15:52:57.326905-0000: -1:kenwood.c(4881):kenwood_get_powerstat returning(0) 2023-01-09T15:52:57.326921-0000: -2:rig.c(6045):rig_get_powerstat returning(0) 2023-01-09T15:52:57.326936-0000: rigctl_parse: rig_powerstat is not on = 0 2023-01-09T15:52:57.326951-0000: rigctl_parse: command get_freq not allowed when rig is powered off 2023-01-09T15:52:57.326966-0000: rigctl_parse: called, interactive=1
The text was updated successfully, but these errors were encountered:
Fix get_powerstat status return to always show POWER_ON for kenwood n…
d2ef9d5
…on-PS rigs #1213
eea9901
Add TS-2000 to has_ps exceptions
c3ff7e1
#1213
a03d589
No branches or pull requests
I just updated our hamlib package to 4.5.3 in Mageia and also updated to
wsjtx-2 6.0 at the same time.
Now klog and wsjtx are broken with my radio at least!
If you want more info please ask and I will create some more logs as usual.
It's strange that freqMainA=14299390 (which is correct) yet:
rig_powerstat is not on = 0 is that logic reversed?
Anyway over to you :)
BTW Happy New Year!
Barry
2023-01-09T15:52:52.732355-0000: rig_get_mode(2534): freqMainA=14299390,
modeMainA=USB, widthMainA=2700
2023-01-09T15:52:52.732371-0000: rig_get_mode(2534): freqMainB=7073000,
modeMainB=, widthMainB=0
2023-01-09T15:52:52.732388-0000: -1:rig_get_mode:
elapsed=38ms
2023-01-09T15:52:52.732403-0000:
-1:rig.c(2537):rig_get_mode returning(0)
2023-01-09T15:52:52.732419-0000:
-2:rig.c(1370):rig_open returning(0)
Opened rig model 2003, 'TS-450S'
2023-01-09T15:52:52.732448-0000: Backend version: 20221230.0, Status: Stable
2023-01-09T15:52:52.732462-0000: rigctl_parse: called, interactive=1
Rig command: f
2023-01-09T15:52:57.326794-0000: rigctl_parse: cmd=f(66) handle=0
2023-01-09T15:52:57.326824-0000: rigctl_parse: vfo_opt=0
2023-01-09T15:52:57.326858-0000:
-2:rig.c(6023):rig_get_powerstat entered
2023-01-09T15:52:57.326875-0000: rig.c(6043) trace
2023-01-09T15:52:57.326889-0000:
-1:kenwood.c(4877):kenwood_get_powerstat entered
2023-01-09T15:52:57.326905-0000:
-1:kenwood.c(4881):kenwood_get_powerstat returning(0)
2023-01-09T15:52:57.326921-0000:
-2:rig.c(6045):rig_get_powerstat returning(0)
2023-01-09T15:52:57.326936-0000: rigctl_parse: rig_powerstat is not on = 0
2023-01-09T15:52:57.326951-0000: rigctl_parse: command get_freq not
allowed when rig is powered off
2023-01-09T15:52:57.326966-0000: rigctl_parse: called, interactive=1
The text was updated successfully, but these errors were encountered: