Notifications
You must be signed in to change notification settings - Fork 0
/
CP-PCD-071-00.txt
230 lines (197 loc) · 14.7 KB
/
CP-PCD-071-00.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
Tracking information:
|IHE Domain |Patient Care Devices |
|Change Proposal ID: |CP-PCD-071-00 |
|Change Proposal Status: |Ballot |
|Date of last update: |2012-06-08 |
|Person assigned: |John Rhoads |
Change Proposal Summary information:
|WS-Addressing error resolution |
|Submitter’s Name(s) and e-mail | |
|address(es): | |
|Submission Date: |2012-06-08 |
|Integration Profile(s) affected: |DEC |
|Actor(s) affected: |DOR, DOC |
|IHE Technical Framework or |IHE Patient Care Device (PCD) |
|Supplement modified: |Technical Framework; Volume 2; |
| |Revision 1.0; August 12, 2011 |
|Volume(s) and Section(s) affected: |Vol. 2 |
|Rationale for Change: |
|Add appendix material on Message Transport using WS* which was formerly in|
|the Trial Implementation version but not in Final Text because it formerly|
|was not backed up by sufficient testing in the consensus of the PCD |
|Technical Committee, but which has now had suficient testing. |
|Clarification was also added that WS-Addressing elements, although not |
|required and not expected by some testing tools, was |
Insert the following:
Appendix J Message Transport using WS*
IHE PCD HL7 V2 messages may be sent over Web Services (WS*).
The IHE IT Infrastructure Technical Framework Volume 2x Appendix V provides
guidance regarding the appropriate WSDL files, schema and sample XML
messages. The following artifacts are provided here as informative
implementations and should match the versions found in the IHE
ftp://ftp.ihe.net/TF_Implementation_Material/ for PCD. If a later version
is available at the ftp site, it should be used.
1 Sample WSDL file and schema
The Web Services Description Language (WSDL) is a W3C standard designed to
define a web service through concrete endpoints and operations. The IHE IT
Infrastructure Technical Framework Volume 2x Appendix V provides guidance
on deriving WSDL files from an IHE transaction.
Non-normative illustrative examples of an WSDL file
«DeviceObservationConsumer.wsdl» and schema «DeviceObservationConsumer.xsd»
are shown below:
|DeviceObservationConsumer.wsdl |
|<?xml version="1.0" encoding="UTF-8"?> |
|<wsdl:definitions name="DeviceObservationConsumer" |
|targetNamespace="urn:ihe:pcd:dec:2010" |
|xmlns:soap12="http://schemas.xmlsoap.org/wsdl/soap12/" |
|xmlns:wsdl="http://schemas.xmlsoap.org/wsdl/" |
|xmlns:xsd="http://www.w3.org/2001/XMLSchema" |
|xmlns:wsaw="http://www.w3.org/2006/05/addressing/wsdl" |
|xmlns:tns="urn:ihe:pcd:dec:2010"> |
|<wsdl:types> |
|<xsd:schema> |
|<xsd:import namespace="urn:ihe:pcd:dec:2010" |
|schemaLocation="DeviceObservationConsumer.xsd"/> |
|</xsd:schema> |
|</wsdl:types> |
|<wsdl:message name="CommunicatePCDData_Message"> |
|<wsdl:documentation>Communicate PCD Data</wsdl:documentation> |
|<wsdl:part name="body" element="tns:CommunicatePCDData"/> |
|</wsdl:message> |
|<wsdl:message name="CommunicatePCDDataResponse_Message"> |
|<wsdl:documentation>Communicate PCD Data Response</wsdl:documentation> |
|<wsdl:part name="body" element="tns:CommunicatePCDDataResponse"/> |
|</wsdl:message> |
|<wsdl:portType name="DeviceObservationConsumer_PortType"> |
|<wsdl:operation name="CommunicatePCDData"> |
|<wsdl:input message="tns:CommunicatePCDData_Message" |
|wsaw:Action="urn:ihe:pcd:2010:CommunicatePCDData"/> |
|<wsdl:output message="tns:CommunicatePCDDataResponse_Message" |
|wsaw:Action="urn:ihe:pcd:2010:CommunicatePCDDataResponse"/> |
|</wsdl:operation> |
|</wsdl:portType> |
|<wsdl:binding name="DeviceObservationConsumer_Binding_Soap12" |
|type="tns:DeviceObservationConsumer_PortType"> |
|<soap12:binding style="document" |
|transport="http://schemas.xmlsoap.org/soap/http"/> |
|<wsaw:UsingAddressing wsdl:required="true"/> |
|<wsdl:operation name="CommunicatePCDData"> |
|<soap12:operation soapAction="urn:ihe:pcd:2010:CommunicatePCDData" |
|soapActionRequired=""/> |
|<wsdl:input> |
|<soap12:body use="literal"/> |
|</wsdl:input> |
|<wsdl:output> |
|<soap12:body use="literal"/> |
|</wsdl:output> |
|</wsdl:operation> |
|</wsdl:binding> |
|<wsdl:service name="DeviceObservationConsumer_Service"> |
|<wsdl:port name="DeviceObservationConsumer_Port_Soap12" |
|binding="tns:DeviceObservationConsumer_Binding_Soap12"> |
|<soap12:address location="http://www.example.org/"/> |
|</wsdl:port> |
|</wsdl:service> |
|</wsdl:definitions> |
Note: the element <wsaw:UsingAddressing wsdl:required="true"/> is required
for strict conformance to IHE ITI Technical Framework Vol. 2x, Appendix V
(and is required by IHE testing tools), but readers are warned that some
web services infrastructure implementation will not use or recognize it, so
it is well if feasible to be prepared to include it or not, to be prepared
to deal with both situations.
|DeviceObservationConsumer.xsd |
|<?xml version="1.0" encoding="UTF-8"?> |
|<schema xmlns="http://www.w3.org/2001/XMLSchema" |
|xmlns:tns="urn:ihe:pcd:dec:2010" targetNamespace="urn:ihe:pcd:dec:2010"> |
|<element name="CommunicatePCDData" type="tns:UnsolicitedObservationResult"/> |
|<element name="CommunicatePCDDataResponse" type="tns:GeneralAckowledgement"/> |
|<simpleType name="UnsolicitedObservationResult"> |
|<restriction base="string"/> |
|</simpleType> |
|<simpleType name="GeneralAckowledgement"> |
|<restriction base="string"/> |
|</simpleType> |
|</schema> |
2 Sample PCD-01 message and response
In addition to the WSDL-related rules found in Appendix V of the IHE ITI
Technical Framework Volume 2, the framework contains a number of
conformance constraints for web service consumers and providers. These
rules were developed to improve IHE-related web service interoperability
and PCD implementations using web services are required to comply.
Note that the contents of the urn:ihe:pcd:dec:2010:CommunicatePCDData
element must contain the entire contents of a valid PCD-01 Observation
Result message. However, based on the character restrictions of XML and
web services, there are a number of characters that cannot be used in their
literal form (see http://www.w3.org/International/questions/qa-
controls#support for more information).
Restricted characters, such as "&” and "<cr>", must be escaped using XML
predefined character entity references wherever possible (e.g., &).
For restricted characters that have no predefined character entity
references, a numeric character references should be used instead (e.g.,
&#d;). Messages containing characters which are prohibited from use in XML
in both literal and escaped format are prohibited from being sent using the
WS* transport profile.
For a complete list of excluded characters, please see the XML
specification at http://www.w3.org/TR/xml/#syntax
Examples of a Communicate PCD Data message «CommunicatePCDData.xml» and a
typical response «CommunicatePCDDataResponse.xml» are shown below
(informative).
|CommunicatePCDData.xml |
|<?xml version="1.0" encoding="UTF-8"?> |
|<soapenv:Envelope xmlns:soapenv="http://www.w3.org/2003/05/soap-envelope"> |
|<soapenv:Header xmlns:wsa="http://www.w3.org/2005/08/addressing"> |
|<wsa:To soapenv:mustUnderstand="true"> |
|http://localhost:9097/org.openhealthtools.stepstone.backend.gateway/DeviceObse|
|rvationConsumer_Service |
|</wsa:To> |
|<wsa:From soapenv:mustUnderstand="true"> |
|<wsa:Address> |
|http://www.w3.org/2005/08/addressing/anonymous |
|</wsa:Address> |
|</wsa:From> |
|<wsa:MessageID soapenv:mustUnderstand="true"> |
|urn:uuid:A52590343911955D1A1251497585530 |
|</wsa:MessageID> |
|<wsa:Action soapenv:mustUnderstand="true"> |
|urn:ihe:pcd:2010:CommunicatePCDData |
|</wsa:Action> |
|</soapenv:Header> |
|<soapenv:Body> |
|<CommunicatePCDData xmlns="urn:ihe:pcd:dec:2010"> |
|MSH|^~\&|AcmeInc^ACDE48234567ABCD^EUI-64||||20090713090030+0500||ORU^R01^O|
|RU_R01|MSGID1234|P|2.6|||NE|AL|||||IHE PCD ORU-R01 |
|2006^HL7^2.16.840.1.113883.9.n.m^HL7
 |
|PID|||789567^^^Imaginary Hospital^PI||Doe^John^Joseph^^^^L^A|||M
 |
|OBR|1|AB12345^AcmeAHDInc^ACDE48234567ABCD^EUI-64|CD12345^AcmeAHDInc^ACDE482345|
|67ABCD^EUI-64|528391^MDC_DEV_SPEC_PROFILE_BP^MDC|||20090813095715+0500
 |
|OBX|1||528391^MDC_DEV_SPEC_PROFILE_BP^MDC|1|||||||R|||||||0123456789ABCDEF^EUI|
|-64
 |
|OBX|2||150020^MDC_PRESS_BLD_NONINV^MDC|1.0.1||||||R|||20090813095715+0500
|
|OBX|3|NM|150021^MDC_PRESS_BLD_NONINV_SYS^MDC|1.0.1.1|120|266016^MDC_DIM_MMHG^M|
|DC||||R
 |
|OBX|4|NM|150022^MDC_PRESS_BLD_NONINV_DIA^MDC|1.0.1.2|80|266016^MDC_DIM_MMHG^MD|
|C||||R
 |
|OBX|5|NM|150023^MDC_PRESS_BLD_NONINV_MEAN^MDC|1.0.1.3|100|266016^MDC_DIM_MMHG^|
|MDC||||R
 |
|</CommunicatePCDData> |
|</soapenv:Body> |
|</soapenv:Envelope> |
|CommunicatePCDDataResponse.xml |
|<?xml version="1.0" encoding="UTF-8"?> |
|<soapenv:Envelope xmlns:soapenv="http://www.w3.org/2003/05/soap-envelope"> |
|<soapenv:Header xmlns:wsa="http://www.w3.org/2005/08/addressing"> |
|<wsa:Action> |
|urn:ihe:pcd:2010:CommunicatePCDDataResponse |
|</wsa:Action> |
|<wsa:RelatesTo> |
|urn:uuid:F8C3FF2964F94E404E1251145112405 |
|</wsa:RelatesTo> |
|</soapenv:Header> |
|<soapenv:Body> |
|<CommunicatePCDDataResponse xmlns="urn:ihe:pcd:dec:2010"> |
|MSH|^~\&|Stepstone||AcmeInc^ACDE48234567ABCD^EUI64||20090726095731+0500||ACK^A01^|
|ACK|AMSGID1234|P|2.6|
 |
|MSA|AA|MSGID1234|Message Accepted|
 |
|</CommunicatePCDDataResponse> |
|</soapenv:Body> |
|</soapenv:Envelope> |