removed the mfact parameter and implemented m properly #58
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Fixes #25
As mentioned in the discussion, this fix is not ideal, but it seems this is how the original spectre SG13G2 model extractors did it. One main open question is the parameter
m
, which is used in the scaling of the PSP model parametervfbo
.This can not be verified at the moment since in the current available measurements there are no multi-finger device measurements present.