Notifications
You must be signed in to change notification settings - Fork 331
/
DCS52.shtml
361 lines (304 loc) · 18.4 KB
/
DCS52.shtml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01//EN"
"http://www.w3.org/TR/html4/strict.dtd">
<html lang="en">
<head>
<title>JMRI Hardware Support - Connecting to a Digitrax DCS52</title>
<meta name="author" content="Bob Jacobsen">
<meta name="author" content="B. Milhaupt">
<meta name="keywords" content=
"Digitrax DCS Command Station DCS52 java model railroad JMRI install windows">
<!-- Style -->
<meta http-equiv="Content-Type" content=
"text/html; charset=us-ascii">
<link rel="stylesheet" type="text/css" href="/css/default.css"
media="screen">
<link rel="stylesheet" type="text/css" href="/css/print.css"
media="print">
<link rel="icon" href="/images/jmri.ico" type="image/png">
<link rel="home" title="Home" href="/"><!-- /Style -->
</head>
<body>
<!--#include virtual="/Header" -->
<div class="nomenu" id="mBody">
<div id="mainContent">
<h1>Hardware Support: Connecting to a Digitrax DCS52</h1><br>
<p>JMRI may be connected to the Digitrax DCS52 in any
of a wide variety of ways. Since the DCS52 has a built-in USB interface,
it is possible to simply plug a USB cable into the computer and the DCS52,
and configure JMRI to suit this connection. It is also possible to use
another LocoNet interface device, such as a LocoBuffer-USB, Digitrax PR3,
or Digitrax PR4, to interface a computer to LocoNet, and connect that LocoNet
to the DCS52. JMRI does not prefer any one connection method over any
other method. Choose one which is suitable for your needs.</p>
<p>If a USB cable is used to connect the JMRI computer to the DCS52's USB
connection, JMRI may be configured in one of two modes. If the computer
will only be used for decoder programming, and JMRI will not need access to
LocoNet features other than the DCS52 "programming track", then JMRI may
be configured to use a "connection" where the DCS52 USB interface is
placed into a mode where it acts as a standalone decoder
programmer. In this mode, JMRI will access the DCS52 dedicated
programming track connections. This mimics the "standalone programmer"
configuration which the PR2 provides, and which the PR3 and PR4 can support.</p>
<p>Alternately, when JMRI will be used to access LocoNet resources which
go beyond simply the DCS52 programming track, then JMRI should be configured
to act as a general-purpose LocoNet interface. The JMRI "connection" should
be configured so that the "command station" type specifies the type of
command station which is being used.</p>
<p>The table below summarizes these possibilities.</p>
<table border="3">
<tr><td align="center" rowspan="2"><strong>Connection Type</strong></td>
<td align="center" rowspan="2"><strong>Usage</strong></td>
<td colspan="2" align="center"><strong>Settings in JMRI Connection Profile</strong></td>
<td align="center" rowspan="2"><strong>Available JMRI Capabilities</strong></td></tr>
<tr><td align="center"><strong>System Connection</strong></td>
<td align="center"><strong>JMRI Command Station Type</strong></td></tr>
<tr><td rowspan="9" align="center">USB cable from computer to DCS52 USB connector</td>
<td rowspan="2" align="center">Decoder Programming</td>
<td rowspan="2" align="center">"<em>DCS52 USB Interface</em>"</td>
<td rowspan="2" align="center">"<em>DCS52 Standalone Programmer</em>"</td>
<td>Program decoder CVs on the dedicated programming track</td></tr>
<tr><td>Operate one loco on the dedicated programming track</td>
<tr><td rowspan="7" align="center">LocoNet Interface, Decoder Programming</td>
<td rowspan="7" align="center">"<em>DCS52 USB Interface</em>"</td>
<td rowspan="7" align="center">"<em>DCS52 (Zephyr Express Command Station)</em>"</td>
<td>Program decoder CVs on the dedicated programming track and/or the main track</td></tr>
<tr><td>Control one or more locos on the main track</td></tr>
<tr><td>Control and monitor LocoNet-connected Switches, Sensors, and Transponding</td></tr>
<tr><td>Configure some LocoNet devices</td></tr>
<tr><td>Control or monitor the LocoNet Fast Clock</td></tr>
<tr><td>Update firmware on some LocoNet devices</td></tr>
<tr><td>etc.</td></tr>
<tr><td rowspan="7" align="center">LocoNet Interface, Decoder Programming</td>
<td rowspan="7" align="center">Computer Connection to something other than the DCS52 USB connector</td>
<td rowspan="7" align="center">Something other than "DCS52 USB Interface"</td>
<td rowspan="7" align="center">"<em>DCS52 (Zephyr Express Command Station)</em>"</td>
<td>Program decoder CVs on the dedicated programming track</td></tr>
<tr><td>Control one or more locos on the main track</td></tr>
<tr><td>Control and monitor LocoNet-connected Switches, Sensors, and Transponding</td></tr>
<tr><td>Configure some LocoNet devices</td></tr>
<tr><td>Control or monitor the LocoNet Fast Clock</td></tr>
<tr><td>Update firmware on some LocoNet devices</td></tr>
<tr><td>etc.</td></tr>
</table>
<p>Note that it is possible to use the DCS52 in a "booster" mode, and rely upon
some other command station. If this configuration is used, the "command station"
specified for the JMRI connection should match the device which is actually
acting as the command station.</p>
<h2>Choosing the configuration profile "command station" setting</h2>
<p>When setting up a JMRI "connection profile", which "command station" should
you use when configuring JMRI? That depends on what you
intend to do with JMRI.</p>
<ul>
<li>If you will <em>only</em> use JMRI to program decoders on
the dedicated programming track, then configuring the connection for the
"command station" type of "DCS52 Standalone Programmer" mode
is a good choice. In this mode, JMRI will be able to read and write decoder
CV values. In this mode, you may also use a JMRI throttle to select and
control the locomotive on the dedicated programming track, subject to the
ability of the DCS52 to supply sufficient current to the decoder. JMRI will
<em>not</em> be able to access LocoNet peripherals and JMRI throttles will <em>not</em>
be able to control decoders via the "main track".</li>
<li><p>If you wish JMRI to be able to control decoders via the DCS52 main track
outputs, and access LocoNet devices, then configuring the connection for the
"command station" type of "DCS52 Standalone Programmer" mode
is a good choice. In this mode, JMRI is able to control decoders connected
via the main track outputs and access LocoNet devices. JMRI may also
perform decoder programming via the dedicated programming track, but JMRI
throttles will <em>not</em> be able to run decoders which are on the dedicated
programming track.</p></li>
<li>If you think that both modes may be useful to you, you should consider
setting up <em>two</em> configuration profiles. Then, when you start
JMRI, you may select the configuration profile which suits the way you want
to use JMRI. And to switch to the other mode, you may simply quit JMRI and
re-start it, and select the other profile, so that you may perform the other
type of work.</li>
</ul>
<h2>DCS52 USB interface as a stand-alone decoder programmer</h2>
<p><img src="images/DCS52StandaloneProgrammerConnections.png"
alt="Typical connections for DCS52 for use as standalone programmer"
width="300"></p>
<p>When the DCS52 USB interface is configured to act as a programmer, it acts
upon the dedicated programming track via the "programming track" connections
on the DCS52. When JMRI is properly configured, JMRI
can use the DCS52 programming track to access decoder CVs when the decoder is
connected to the programming track.</p>
<p>This JMRI configuration may also be used to download sound information into
Digitrax sound decoders and, within its limited current
capability, run one locomotive to test it. When used with
Digitrax SFX decoders, "neutral mode" allows you to vary the
speed without the motor moving the decoder, so you can hear
how the locomotive sound reacts to varying speeds.</p>
<p>In this mode of operations, JMRI will not have access to LocoNet-based
devices.</p>
<h3>Setup for the DCS52 acting as a standalone programmer</h3>
<p>To use the DCS52 programming track, connect the DCS52 to its
power supply and connect a dedicated piece of track which you'll
use as the programming track to the DCS52 "programming track"
terminals. Finally, connect a USB cable
between the DCS52 and your computer.</p>
<p>To set up JMRI to use the DCS52 via the dedicated
decoder programming track mode:</p>
<ul>
<li>Start the program.</li>
<li>Open the Preferences window from the Edit menu and
configure the connection by:
<ul>
<li>For the "<strong>System Connection</strong>" setting, select "DCS52 USB Interface"</li>
<li>Under "<strong>Serial Port</strong>", select the serial port that's connected to the
DCS52</li>
<li>In the "<strong>Command station type</strong>" option,
select the type of command station you've got on your
LocoNet. Typically, this will be "<code><strong>DCS52
USB Interface as standalone programmer</strong></code>".</li>
<li>In the advanced settings, the speed will be fixed
at 57,600 baud.</li>
<li>In the advanced settings, the "Flow Control" option
defaults to "Use Hardware Flow Control", which is the
preferred setting for the DCS52. You should try that
first, as it is the most reliable mode. Only if you
can't reliably program decoders using that choice, and
only after checking that you're using the right port,
should you select "None" for this preference and try
again.</li>
</ul>
</li>
<li>Click Save at the bottom of the preferences window,
quit the program and restart.</li>
</ul>
<p>The "connection" preferences should look similar to this image:</p>
<img src="images/DCS52StandConnProfile.png" alt="Sample configuration profile with DCS52 USB interface as a standalone programmer" width="500">
<h3>DCS52 USB Interface in Standalone Programming Mode Usage Hints</h3>
<ul>
<li>You can use a JMRI throttle to control the locomotive
connected to the DCS52 Programmer track. Use the JMRI Power Control
or the "Power" menu item on the Throttle's menu bar to turn
on track power, and then you can operate the locomotive
normally via a JMRI throttle.</li>
<li>The DCS52 can only provide very limited current to the programming track, so Digitrax
has built a "neutral mode" into their sound decoders. When
JMRI and the DCS52 is running a Digitrax sound decoder, the
motor is disconnected to reduce the current load. You can
still ramp the speed up and down with the throttle and listen
to how the sound responds, but the motor won't move the
locomotive.
<ul>
<li>To implement that "neutral mode" described
above, the DCS52 automatically writes CV128 to 0 or 1. This
happens when a JMRI throttle is used to run the locomotive on
the DCS52 programming track, and there's nothing JMRI can do to
prevent it. Unfortunately, this can interfere with the CV
programming on some non-Digitrax decoders. For example, it
will set the "Master Volume" CV128 on some SoundTraxx
decoders to a very low volume.</li>
<li>If you are working with a decoder that uses CV128
for something, you should either not use a JMRI throttle to
run the locomotive on the DCS52 programming track, or remember
to rewrite CV128 with the right value just before removing
the locomotive from the track.</li>
</ul></li>
<li>Other decoders, including decoders from other
manufacturers, may draw enough motor current to trip the DCS52
internal circuit breakers. This will cause JMRI to mark track
power as "off". Just wait a couple seconds and turn the track
power back on to recover.</li>
<li>If the DCS52 is in its "Decoder CV programming" mode and JMRI is used to
access decoder CVs, then the DCS52 display may show programming-related
information that is not strictly accurate. This is because the DCS52
cannot easily discriminate between CV accesses made via its keypad and
CV accesses made via other sources.</li>
<li>It is possible run trains via the DCS52 controls and/or LocoNet-based
throttles when JMRI is programming a decoder on the DCS52 programming track.</li>
</ul>
<h2>DCS52 USB interface as a LocoNet Interface</h2>
<p><img src="images/DCS52LocoNetInterfaceConnections.png"
alt="Typical connections for DCS52 acting as a LocoNet interface"
width="300"></p>
<p>When acting as an interface, the DCS52 USB connection allows JMRI to
interact with devices connected to LocoNet. This includes
programming decoders on a programming track attached to a
LocoNet command station. Where the LocoNet command station
supports "programming on the main", JMRI is able to make use
of that feature.</p>
<h3>Setup for the DCS52 acting as a LocoNet interface</h3>
<p>To use the DCS52 USB connection as a LocoNet interface, connect a LocoNet cable to
a LocoNet connector on the DCS52. Connect an appropriate power
supply to the DCS52, per the Digitrax instructions for the DCS52. The
DCS52 USB interface will not be able to communicate with LocoNet unless
the DCS52 is properly powered. Finally, connect an appropriate USB cable between the
DCS52 USB connector and your computer.</p>
<p>To set up a JMRI application to use the DCS52 as an
interface to a LocoNet which includes a LocoNet command
station:</p>
<ul>
<li>Start the program.</li>
<li>Open the Preferences window from the Edit menu and
configure the connection by:
<ul>
<li>For the "<strong>System Connection</strong>" setting, select "DCS52 USB Interface"</li>
<li>Under "<strong>Serial Port</strong>", select the serial port that's connected to the
DCS52</li>
<li>In the "<strong>Command station type</strong>" option,
select the type of command station you've got on your
LocoNet. Typically, this will be "<code><strong>DCS52
(Zephyr Express command station)</strong></code>", but, if you have configured
your DCS52 to act only as a booster, you should select the command
station option which matches the active command station.</li>
<li>In the advanced settings, the speed will be fixed
at 57,600 baud.</li>
<li>In the advanced settings, the "Flow Control" option
defaults to "Use Hardware Flow Control", which is the
preferred setting for the DCS52. You should try that
first, as it is the most reliable mode. Only if you
can't reliably program decoders using that choice, and
only after checking that you're using the right port,
should you select "None" for this preference and try
again.</li>
</ul>
</li>
<li>Click Save at the bottom of the preferences window,
quit the program and restart.</li>
</ul>
<p>The "connection" preferences should look similar to this image:</p>
<img src="images/DCS52LocoNetInterfaceConnProfile.png" alt="Sample configuration profile with DCS52 USB interface as a LocoNet interface" width="500">
<h2>DCS52 connected via some other LocoNet Interface</h2>
<p>JMRI may connect to the LocoNet via a LocoNet interface other than the
DCS52 USB connector. When connected in this fashion, see the
JMRI documentation associated with the LocoNet interface which is being
used.</p>
<h1>Drivers</h1>
The DCS52 needs to have a driver installed when used with any Microsoft
Windows Operating System. See the Digitrax
<a href=
"http://www.digitrax.com/downloads/">"Downloads"</a> page for drivers.
At the time this help page was written, Digitrax provides Windows drivers
for the PR3 device. Those drivers are suitable for use with the DCS52.
Make sure to follow any instructions, particularly any instructions
about the order of installing the drivers and plugging in the
device.
<p>You don't need to install a separate driver when using
current versions of Mac OS X or Linux.</p>
<h1>See Also</h1>
<ul>
<li><a href="Digitrax.shtml">JMRI's general Digitrax support page</a></li>
<li>The JMRI <a href="../../apps/DecoderPro/Roster.shtml">Rosters</a> page.</li>
<li>The JMRI <a href="CommandStationConfig.shtml">
Command Station Configuration</a> page describes how to configure
command station OpSw settings.</li>
<li>For more information on the DCS52 itself, please consult the Digitrax
web site:
<ul><li>The Digitrax <a href=
"http://www.digitrax.com/products/command-stations-boosters/DCS52/">DCS52</a> product page.</li>
<li>The Digitrax <a href=
"http://www.digitrax.com/tsd/product/DCS52/">DCS52 Support</a> page.</li>
<li>Drivers for Windows-based machines may be found at the Digitrax
<a href="http://www.digitrax.com/downloads/">Downloads</a> page.
Note: Use the Digitrax PR3 drivers with the DCS52.</li>
</ul>
</ul>
<p>LocoNet® is a registered trademark of <a href=
"http://www.digitrax.com">Digitrax, Inc.</a></p>
<!--#include virtual="/Footer" -->