Revert change to max temperature range for Moes BHT-002, should be 0-35 as originally #4887

Merged
merged 1 commit into from
Nov 5, 2022
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
2 changes: 1 addition & 1 deletion lib/exposes.js
Original file line number Diff line number Diff line change
Expand Up @@ -583,7 +583,7 @@ module.exports = {
max_heat_setpoint_limit: (min, max, step) => new Numeric('max_heat_setpoint_limit', access.ALL).withUnit('°C').withDescription('Maximum Heating set point limit').withValueMin(min).withValueMax(max).withValueStep(step),
min_heat_setpoint_limit: (min, max, step) => new Numeric('min_heat_setpoint_limit', access.ALL).withUnit('°C').withDescription('Minimum Heating set point limit').withValueMin(min).withValueMax(max).withValueStep(step),
max_temperature: () => new Numeric('max_temperature', access.STATE_SET).withUnit('°C').withDescription('Maximum temperature').withValueMin(15).withValueMax(35),
max_temperature_limit: () => new Numeric('max_temperature_limit', access.STATE_SET).withUnit('°C').withDescription('Maximum temperature limit. Cuts the thermostat out regardless of air temperature if the external floor sensor exceeds this temperature. Only used by the thermostat when in AL sensor mode.').withValueMin(20).withValueMax(70),
max_temperature_limit: () => new Numeric('max_temperature_limit', access.STATE_SET).withUnit('°C').withDescription('Maximum temperature limit. Cuts the thermostat out regardless of air temperature if the external floor sensor exceeds this temperature. Only used by the thermostat when in AL sensor mode.').withValueMin(0).withValueMax(35),
min_temperature_limit: () => new Numeric('min_temperature_limit', access.STATE_SET).withUnit('°C').withDescription('Minimum temperature limit for frost protection. Turns the thermostat on regardless of setpoint if the tempreature drops below this.').withValueMin(1).withValueMax(5),
min_temperature: () => new Numeric('min_temperature', access.STATE_SET).withUnit('°C').withDescription('Minimum temperature').withValueMin(1).withValueMax(15),
noise: () => new Numeric('noise', access.STATE).withUnit('dBA').withDescription('The measured noise value'),