title description addedAt pageClass
TuYa LCZ030 control via MQTT
Integrate your TuYa LCZ030 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2021-10-01 17:18:02 UTC
device-page

TuYa LCZ030

Model LCZ030
Vendor TuYa
Description Temperature & humidity & illuminance sensor with display
Exposes temperature, humidity, battery, illuminance, illuminance_lux, alarm_temperature_max, alarm_temperature_min, alarm_humidity_max, alarm_humidity_min, alarm_humidity, alarm_temperature, linkquality
Picture TuYa LCZ030

Notes

Warning

For full functionality of this device you will need to pair it to a TuYa Gateway prior use.

Options

How to use device type specific configuration

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

  • illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.

Exposes

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is 掳C.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Illuminance (numeric)

Raw measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value.

Illuminance (lux) (numeric)

Measured illuminance in lux. Value can be found in the published state on the illuminance_lux property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.

Alarm temperature max (numeric)

Alarm temperature max. Value can be found in the published state on the alarm_temperature_max property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"alarm_temperature_max": NEW_VALUE}. The minimal value is -20 and the maximum value is 80. The unit of this value is 掳C.

Alarm temperature min (numeric)

Alarm temperature min. Value can be found in the published state on the alarm_temperature_min property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"alarm_temperature_min": NEW_VALUE}. The minimal value is -20 and the maximum value is 80. The unit of this value is 掳C.

Alarm humidity max (numeric)

Alarm humidity max. Value can be found in the published state on the alarm_humidity_max property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"alarm_humidity_max": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Alarm humidity min (numeric)

Alarm humidity min. Value can be found in the published state on the alarm_humidity_min property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"alarm_humidity_min": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Alarm humidity (enum)

Alarm humidity status. Value can be found in the published state on the alarm_humidity property. It's not possible to read (/get) or write (/set) this value. The possible values are: below_min_humdity, over_humidity, off.

Alarm temperature (enum)

Alarm temperature status. Value can be found in the published state on the alarm_temperature property. It's not possible to read (/get) or write (/set) this value. The possible values are: below_min_temperature, over_temperature, off.

Linkquality (numeric)