title | description | addedAt | pageClass |
---|---|---|---|
Wally U02I007C.01 control via MQTT |
Integrate your Wally U02I007C.01 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2020-04-08 17:49:06 UTC |
device-page |
Model | U02I007C.01 |
Vendor | Wally |
Description | WallyHome multi-sensor |
Exposes | battery, temperature, humidity, action, contact, water_leak, linkquality |
Picture |
How to use device type specific configuration
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Remaining battery in %, can take up to 24 hours before reported.
Value can be found in the published state on the battery
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Measured temperature value.
Value can be found in the published state on the temperature
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It's not possible to read (/get
) or write (/set
) this value.
The possible values are: on
, off
.
Indicates if the contact is closed (= true) or open (= false).
Value can be found in the published state on the contact
property.
It's not possible to read (/get
) or write (/set
) this value.
If value equals false
contact is ON, if true
OFF.
Indicates whether the device detected a water leak.
Value can be found in the published state on the water_leak
property.
It's not possible to read (/get
) or write (/set
) this value.
If value equals true
water leak is ON, if false
OFF.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.