HRAN - Physiological noise removal for fast fMRI

We created a statistical tool to estimate and remove physiological noise in fast fMRI (Agrawal et al., 2019). Our code is under the MIT license and has no warranty. Below, we describe the steps for implementing the software:

Prerequisites

HRAN was created and tested in MATLAB 2018 and 2019 (MathWorks).

HRAN uses chronux toolbox, available at chronux.

After downloading MATLAB and chronux, please direct your scripts to the appropriate directory by adding the following line:

addpath(genpath('/PATH/chronux'))

where PATH is the path to the chronux directory.

Installing

Our software package HRAN is available at our lab Git - HRAN.

We recommend running the HRAN_demo_nifti.m or HRAN_demo_simulated.m script in order to test if the program was downloaded successfully.

Running

Estimating physiological frequencies

As illustrated in HRAN_demo_nifti.m and HRAN_demo_simulated.m, physiological frequencies are first estimated from an anatomically defined ROI (e.g. the ventricles), with the following input parameters:

% TR, moving window length, percent overlap
inputParams = struct;
inputParams.TR = %TR of fMRI data (s)
inputParams.windowLength = % length of moving window (s) (e.g. 24-30s)
inputParams.percentOverlap = % percent overlap of windows (e.g. .5 or .75)

% Neural regressors of design matrix (time x # regressors)
% Estimated neural signal components to be used in GLM
% e.g. neural stimulus convolved with HRF
neuralZ = [cos(2*pi*neuralFrequency.*time)'; sin(2*pi*neuralFrequency.*time)'];
inputParams.neuralZ = neuralZ;

% Physiological frequency range
inputParams.cardiacFreqRange = % cardiac fundamental freq range (bpm, e.g. 40 - 80)
inputParams.respFreqRange =  %resp fundamental freq range (bpm, e.g. 10 - 20)

% Model orders used to estimate the cardiac and respiratory frequencies
% from physiological time series
inputParams.P_freq = % AR order used to estimate physio frequencies (e.g. 1-4)
inputParams.R_freq = % Resp order used to estimate physio frequencies (e.g. 1-4)
inputParams.C_freq = % Cardiac order used to estimate physio frequencies (e.g. 1-3)
inputParams.N_freq = % Number of neural regressors used to estimate physio freqs (e.g. 0 bc assuming no neural signal in this region)
inputParams.X_freq = % Interaction order used to estimate physio frequencies (e.g. 0-1)

% Model orders used to create design matrix to regress physio noise from
% each voxel in the brain
inputParams.P_Z = % AR order used to regress physio noise (e.g. 1-4)
inputParams.R_Z = % Resp order used to regress physio noise (e.g. 1-4)
inputParams.C_Z = % Cardiac order used to regress physio noise (e.g. 1-3)
inputParams.N_Z = size(neuralZ,2); % Number of neural regressors used to regress physio noise (e.g. number of columns in neuralZ)
inputParams.X_Z = % Interaction order used to regress physio noise (e.g. 0-1)

% Toggle for waitbar on or off
waitbarBoolean = % 1 - on, 0 - off

Then, the function HRAN_estimatePhysFreqs is called with the specified physiologicalData time series and input parameters:

% Run function to estimate physiological frequencies
HRAN_estFreqs_outputParams = HRAN_estimatePhysFreqs(physiologicalData,inputParams,waitbarBoolean);

One should look at the spectrogram of the physiologically noisy region with the estimates of the fundamental frequencies overlaid to confirm that frequencies were estimated correctly (as shown below from HRAN_demo_simulated and HRAN_demo_nifti):

EstFreqs_demo EstFreqs_nifti

Regressing physiological noise from voxels/ROIs

Once the physiological frequencies are known, HRAN can efficiently remove physiological noise across any voxel/ROI.

The output parameters HRAN_estFreqs_outputParams are:

% Parameters stored in HRAN_estFreqs_outputParams:
HRAN_estFreqs_outputParams.TR; % TR of fMRI data
HRAN_estFreqs_outputParams.Z_hat; % design matrices across time
HRAN_estFreqs_outputParams.W_freq; % physiological frequencies across time
HRAN_estFreqs_outputParams.windowIndices; % indices of each segment
HRAN_estFreqs_outputParams.windows; % windows applied to each segment
HRAN_estFreqs_outputParams.P_Z; % AR order
HRAN_estFreqs_outputParams.R_Z; % respiratory order
HRAN_estFreqs_outputParams.C_Z; % cardiac order
HRAN_estFreqs_outputParams.N_Z; % number of neural regressors
HRAN_estFreqs_outputParams.X_Z; % number of interaction terms
HRAN_estFreqs_outputParams.percentOverlap; % percent overlap of windows

These parameters can then be used to regress physiological noise across any voxel/ROI (e.g. data) using HRAN_regressPhysNoise:

deNoisedData = HRAN_regressPhysNoise(data,HRAN_estFreqs_outputParams);

% Additional output parameters are also available:
HRAN_neural %estimated task-relevant signal
HRAN_cardiac %estimated cardiac noise
HRAN_resp %estimated respiratory noise
HRAN_residuals %residuals (note: requires MATLAB Econometrics toolbox)

The de-noised output from the simulated data in HRAN_demo_simulated and HRAN_demo_nifti are shown below:

DenoisedData_demo DenoisedData_nifti

This process can be performed in parallel (e.g. across all voxels in the brain) efficiently using parfor loops in MATLAB. Pseudocode shown below, and written in HRAN_demo_nifti.m to read in a nifti, de-noise the nifti, and write out a de-noised nifti file:

parfor z = 1:zDim
  for y = 1:yDim
    for x = 1:xDim
      deNoisedVoxel = HRAN_regressPhysNoise(voxelData(x,y,z),HRAN_estFreqs_outputParams);
      deNoisedBrain(x,y,z) = deNoisedVoxel;
    end
  end
end

The process computation time can be further reduced by only denoising voxels in the brain (using an anatomically defined brain mask).

Note: Nifti files can be read in/written from MATLAB using niftiread and niftiwrite to accommodate input/output from other commonly used softwares.

Our demo script also contains example code to generate spectrograms, normalized cumulative periodograms, and q-q plots in order to assess our model fit (if the Econometrics toolbox is installed).

Finally, one can implement batch scripts using this code as a base!

Acknowledgments

This project is licensed under the MIT License LICENSE.txt.

Please cite (Agrawal et al., 2019) if you use HRAN.

Questions

Please contact us with any questions at uagrawal61@gmail.com!

About

We created a model to remove physiological noise in fast fMRI without external reference signals.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages