BUG: natural heat tranfer coefficient flag value 4 #10

Open
DanielePlacidoPolito opened this issue Dec 14, 2021 · 0 comments
Open

BUG: natural heat tranfer coefficient flag value 4 #10

DanielePlacidoPolito opened this issue Dec 14, 2021 · 0 comments
Assignees
Labels
bug Something isn't working

Comments

@DanielePlacidoPolito
Copy link
Collaborator

Describe the bug
Flag to select evaluate heat transfer coefficient by natural convection and radiation with the environment using a suitable correlation does not work.

To Reproduce
Steps to reproduce the behavior:

  1. Go to file *coupling.xlsx
  2. Click on sheet HTC_choice
  3. In the matrix, select an allowed interface with the external environment
  4. Set the flag to 4
  5. Save and run the software
  6. See error

Expected behavior
Total heat transfer coefficient with the environment evaluated as the sum of the natural convection heat transfer coefficient (evaluated with a suitable correlation) and the radiative heat transfer coefficient.

Desktop (please complete the following information):

  • OS: Windows 10
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment