-
Notifications
You must be signed in to change notification settings - Fork 237
/
ini_fields.F
56 lines (47 loc) · 1.44 KB
/
ini_fields.F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
#include "PACKAGES_CONFIG.h"
#include "CPP_OPTIONS.h"
C---+----1----+----2----+----3----+----4----+----5----+----6----+----7-|--+----|
CBOP
C !ROUTINE: INI_FIELDS
C !INTERFACE:
SUBROUTINE INI_FIELDS( myThid )
C !DESCRIPTION:
C Initial conditions of the model state variables are set here. For
C continuation runs a restart file will be used. For original runs
C custom rules can be included here.
C !USES:
IMPLICIT NONE
#include "SIZE.h"
#include "EEPARAMS.h"
#include "PARAMS.h"
C !INPUT PARAMETERS:
INTEGER myThid
CEOP
C Set model variables to initial/restart conditions
IF ( startTime .EQ. baseTime .AND. nIter0 .EQ. 0
& .AND. pickupSuff .EQ. ' ' ) THEN
CALL INI_VEL( myThid )
CALL INI_THETA( myThid )
CALL INI_SALT( myThid )
CALL INI_PSURF( myThid )
CALL INI_PRESSURE( myThid )
#ifdef INCLUDE_EP_FORCING_CODE
CALL INI_EP( myThid )
#endif
ELSEIF ( .NOT.useOffLine .OR. nonlinFreeSurf.GT.0 ) THEN
CALL READ_PICKUP( nIter0, myThid )
ENDIF
#ifdef ALLOW_NONHYDROSTATIC
IF ( nonHydrostatic ) THEN
CALL INI_NH_FIELDS( myThid )
ENDIF
#endif /* ALLOW_NONHYDROSTATIC */
#ifdef NONLIN_FRSURF
# ifndef DISABLE_SIGMA_CODE
IF ( selectSigmaCoord.NE.0 ) THEN
CALL UPDATE_ETAWS( startTime, nIter0, myThid )
ENDIF
# endif /* DISABLE_SIGMA_CODE */
#endif /* NONLIN_FRSURF */
RETURN
END