dwipreproc: applytopup volumes & grad matching #1044

Closed
Lestropie opened this issue Jul 11, 2017 · 1 comment
Closed

dwipreproc: applytopup volumes & grad matching #1044

Lestropie opened this issue Jul 11, 2017 · 1 comment
Assignees

Comments

@Lestropie
Copy link
Member

As described here.

  • applytopup may not honour the request for Jabian modulation, and therefore output half the number of volumes expected.

  • Finding matching volumes with corresponding gradients for volume recombination fails to verify that the matched volume has the opposing phase encoding direction, and fails to exit the loop when a match is found for a particular volume.

@Lestropie
Copy link
Member Author

Closed by #1047.