Enhancement Request

Once v24.1-IOFreeze is released, we should update to it.

Detailed Description

https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/InputRulesFiles/Rules23-2-0-to-24-1-0.md
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/OutputRulesFiles/OutputChanges23-2-0-to-24-1-0.md

Major changes

New additions

Minor stuff

Other

  • ComfortViewFactorAngles: remove "Zone Name" field
    • Appears this isn't wrapped; no OS change required?
  • AirflowNetwork:Distribution:Component:Coil: field "Coil Object Type" has new keys
    • Appears this isn't wrapped; no OS change required?
  • ZoneHVAC:ForcedAir:UserDefined, AirTerminal:SingleDuct:UserDefined, Coil:UserDefined, PlantComponent:UserDefined: extra notes
@joseph-robertson joseph-robertson added this to the OpenStudio SDK 3.8.0 milestone Feb 15, 2024
@joseph-robertson joseph-robertson added Pull Request - Ready for CI This pull request if finalized and is ready for continuous integration verification prior to merge. and removed Pull Request - Ready for CI This pull request if finalized and is ready for continuous integration verification prior to merge. labels Feb 22, 2024
@jmarrec
Copy link
Collaborator

jmarrec commented Mar 11, 2024

Why is ElectricEquipment:ITE:AirCooled still "Watts per Zone Floor Area" in OS idd?

OS:ElectricEquipment:ITE:AirCooled:Definition,
  N2 , \field Watts per Zone Floor Area

All of the other SpaceLoadDefinition objects (Lights:Definition, ElectricEquipment:Definition, etc) have

  N2, \field Watts per Space Floor Area

No-one really noticed and bothered to change it probably. It's been like this for ever (6 years, when the object was wrapped: https://github.com/NREL/OpenStudio/blame/develop/src/model/ElectricEquipmentITEAirCooledDefinition.hpp#L68 , and that was before the Space was a thing in E+)

(Also, this object is weird in the sense that it's a SpaceLoadInstance, but it's an HVAC component, which is more a zonal thing than a space one to me)