Add subcooled outlet option to DSG LF IPH model #973

Merged
merged 6 commits into from Mar 7, 2022
Merged

Conversation

tyneises
Copy link
Collaborator

@tyneises tyneises commented Mar 7, 2022

image

@tyneises tyneises added this to the 2021.12.02 Patch 2 milestone Mar 7, 2022
@tyneises tyneises merged commit 07e523d into patch Mar 7, 2022
@tyneises tyneises deleted the lf_dsg_subcooled branch March 7, 2022 16:01
@cpaulgilman cpaulgilman added the requires help revision Requires a Help revision before releasing public version label Mar 8, 2022
@cpaulgilman
Copy link
Collaborator

The new radio button on the System Design page lets users decide between solar field that deliver boiling 2-phase steam (default) or subcooled pressurized water where the outlet remains a single-phase liquid. The outlet temperature of the subcooled case is set relative to the calculated saturation temperature (which in turn is a function of the ‘Heat sink in let pressure’ input) using the new ‘Subcooled dT’ input.

@cpaulgilman cpaulgilman added added to release notes PR and/or issue has been added to release notes for a public release and removed requires help revision Requires a Help revision before releasing public version labels May 31, 2022