## ResStock v3.3.0 (pending)

Features
- Updates and enhancements to the ground source heat pump model; ability to describe detailed geothermal loop inputs ([#1187](https://github.com/NREL/resstock/pull/1187))

Fixes
-

## ResStock v3.2.0
###### December 19, 2023 - [Diff](https://github.com/NREL/resstock/compare/v3.1.1...v3.2.0)

Expand Down
140 changes: 136 additions & 4 deletions docs/read_the_docs/source/workflow_inputs/characteristics.rst
Original file line number Diff line number Diff line change
Expand Up @@ -3034,12 +3034,24 @@ Arguments
- Type
- Choices
- Description
* - ``site_soil_and_moisture_type``
- false
-
- Choice
- "auto", "clay, dry", "clay, mixed", "clay, wet", "gravel, dry", "gravel, mixed", "gravel, wet", "loam, dry", "loam, mixed", "loam, wet", "sand, dry", "sand, mixed", "sand, wet", "silt, dry", "silt, mixed", "silt, wet", "unknown, dry", "unknown, mixed", "unknown, wet"
- Type of soil and moisture. This is used to inform ground conductivity and diffusivity. If not provided, the OS-HPXML default (see `HPXML Site <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site>`_) is used.
* - ``site_ground_conductivity``
- false
- Btu/hr-ft-F
- Double
- "auto"
- Conductivity of the ground soil. If not provided, the OS-HPXML default (see `HPXML Site <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site>`_) is used.
-
- Conductivity of the ground soil. If provided, overrides the previous site and moisture type input.
* - ``site_ground_diffusivity``
- false
- ft^2/hr
- Double
-
- Diffusivity of the ground soil. If provided, overrides the previous site and moisture type input.

.. _hvac_cooling_efficiency:

Expand Down Expand Up @@ -3105,7 +3117,7 @@ Arguments
-
- Choice
- "auto", "single stage", "two stage", "variable speed"
- The compressor type of the cooling system. Only applies to central air conditioner. If not provided, the OS-HPXML default (see `Central Air Conditioner <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner>`_) is used.
- The compressor type of the cooling system. Only applies to central air conditioner and mini-split. If not provided, the OS-HPXML default (see `Central Air Conditioner <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner>`_, `Mini-Split Air Conditioner <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-air-conditioner>`_) is used.
* - ``cooling_system_cooling_sensible_heat_fraction``
- false
- Frac
Expand Down Expand Up @@ -3451,7 +3463,7 @@ Arguments
-
- Choice
- "auto", "single stage", "two stage", "variable speed"
- The compressor type of the heat pump. Only applies to air-to-air. If not provided, the OS-HPXML default (see `Air-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump>`_) is used.
- The compressor type of the heat pump. Only applies to air-to-air and mini-split. If not provided, the OS-HPXML default (see `Air-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump>`_, `Mini-Split Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-heat-pump>`_) is used.
* - ``heat_pump_cooling_sensible_heat_fraction``
- false
- Frac
Expand Down Expand Up @@ -3548,6 +3560,66 @@ Arguments
- Double
- "auto"
- Heat Pump crankcase heater power consumption in Watts. Applies only to air-to-air, mini-split, packaged terminal heat pump and room air conditioner with reverse cycle. If not provided, the OS-HPXML default (see `Air-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump>`_, `Mini-Split Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-heat-pump>`_, `Packaged Terminal Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#packaged-terminal-heat-pump>`_, `Room Air Conditioner w/ Reverse Cycle <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#room-air-conditioner-w-reverse-cycle>`_) is used.
* - ``geothermal_loop_configuration``
- false
-
- Choice
- "auto", "none", "vertical"
- Configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `Ground-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#ground-to-air-heat-pump>`_) is used.
* - ``geothermal_loop_borefield_configuration``
- false
-
- Choice
- "auto", "Rectangle", "Open Rectangle", "C", "L", "U", "Lopsided U"
- Borefield configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_loop_flow``
- false
- gpm
- Double
-
- Water flow rate through the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_count``
- false
- #
- Integer
-
- Number of boreholes. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_length``
- false
- ft
- Double
-
- Average length of each borehole (vertical). Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_spacing``
- false
- ft
- Double
- "auto"
- Distance between bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_diameter``
- false
- in
- Double
- "auto"
- Diameter of bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_grout_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Grout type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Pipe type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_diameter``
- false
- in
- Choice
- "auto", "3/4" pipe", "1" pipe", "1-1/4" pipe"
- Pipe diameter of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``heating_system_has_flue_or_chimney``
- true
-
Expand Down Expand Up @@ -3912,6 +3984,66 @@ Arguments
- Choice
- "auto", "ACCA", "HERS", "MaxLoad"
- The auto-sizing methodology to use when the heat pump capacity is not provided. If not provided, the OS-HPXML default (see `HPXML HVAC Sizing Control <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-hvac-sizing-control>`_) is used.
* - ``geothermal_loop_configuration``
- false
-
- Choice
- "auto", "none", "vertical"
- Configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `Ground-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#ground-to-air-heat-pump>`_) is used.
* - ``geothermal_loop_borefield_configuration``
- false
-
- Choice
- "auto", "Rectangle", "Open Rectangle", "C", "L", "U", "Lopsided U"
- Borefield configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_loop_flow``
- false
- gpm
- Double
-
- Water flow rate through the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_count``
- false
- #
- Integer
-
- Number of boreholes. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_length``
- false
- ft
- Double
-
- Average length of each borehole (vertical). Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_spacing``
- false
- ft
- Double
- "auto"
- Distance between bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_diameter``
- false
- in
- Double
- "auto"
- Diameter of bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_grout_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Grout type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Pipe type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_diameter``
- false
- in
- Choice
- "auto", "3/4" pipe", "1" pipe", "1-1/4" pipe"
- Pipe diameter of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``heating_system_has_flue_or_chimney``
- true
-
Expand Down
150 changes: 147 additions & 3 deletions measures/ResStockArguments/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -85,9 +85,22 @@ Presence of nearby buildings, trees, obstructions for infiltration model. If not

<br/>

**Site: Soil and Moisture Type**

Type of soil and moisture. This is used to inform ground conductivity and diffusivity. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site'>HPXML Site</a>) is used.

- **Name:** ``site_soil_and_moisture_type``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `clay, dry`, `clay, mixed`, `clay, wet`, `gravel, dry`, `gravel, mixed`, `gravel, wet`, `loam, dry`, `loam, mixed`, `loam, wet`, `sand, dry`, `sand, mixed`, `sand, wet`, `silt, dry`, `silt, mixed`, `silt, wet`, `unknown, dry`, `unknown, mixed`, `unknown, wet`

<br/>

**Site: Ground Conductivity**

Conductivity of the ground soil. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site'>HPXML Site</a>) is used.
Conductivity of the ground soil. If provided, overrides the previous site and moisture type input.

- **Name:** ``site_ground_conductivity``
- **Type:** ``String``
Expand All @@ -96,6 +109,17 @@ Conductivity of the ground soil. If not provided, the OS-HPXML default (see <a h

<br/>

**Site: Ground Diffusivity**

Diffusivity of the ground soil. If provided, overrides the previous site and moisture type input.

- **Name:** ``site_ground_diffusivity``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Site: Zip Code**

Zip code of the home address.
Expand Down Expand Up @@ -1525,7 +1549,7 @@ The rated efficiency value of the cooling system. Ignored for evaporative cooler

**Cooling System: Cooling Compressor Type**

The compressor type of the cooling system. Only applies to central air conditioner. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner'>Central Air Conditioner</a>) is used.
The compressor type of the cooling system. Only applies to central air conditioner and mini-split. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner'>Central Air Conditioner</a>, <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-air-conditioner'>Mini-Split Air Conditioner</a>) is used.

- **Name:** ``cooling_system_cooling_compressor_type``
- **Type:** ``Choice``
Expand Down Expand Up @@ -1704,7 +1728,7 @@ The rated cooling efficiency value of the heat pump.

**Heat Pump: Cooling Compressor Type**

The compressor type of the heat pump. Only applies to air-to-air. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump'>Air-to-Air Heat Pump</a>) is used.
The compressor type of the heat pump. Only applies to air-to-air and mini-split. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump'>Air-to-Air Heat Pump</a>, <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-heat-pump'>Mini-Split Heat Pump</a>) is used.

- **Name:** ``heat_pump_cooling_compressor_type``
- **Type:** ``Choice``
Expand Down Expand Up @@ -1903,6 +1927,126 @@ Heat Pump crankcase heater power consumption in Watts. Applies only to air-to-ai

<br/>

**Geothermal Loop: Configuration**

Configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#ground-to-air-heat-pump'>Ground-to-Air Heat Pump</a>) is used.

- **Name:** ``geothermal_loop_configuration``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `none`, `vertical`

<br/>

**Geothermal Loop: Borefield Configuration**

Borefield configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_borefield_configuration``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `Rectangle`, `Open Rectangle`, `C`, `L`, `U`, `Lopsided U`

<br/>

**Geothermal Loop: Loop Flow**

Water flow rate through the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_loop_flow``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Count**

Number of boreholes. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_count``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Length**

Average length of each borehole (vertical). Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_length``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Spacing**

Distance between bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_spacing``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Diameter**

Diameter of bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_diameter``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Grout Type**

Grout type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_grout_type``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `standard`, `thermally enhanced`

<br/>

**Geothermal Loop: Pipe Type**

Pipe type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_pipe_type``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `standard`, `thermally enhanced`

<br/>

**Geothermal Loop: Pipe Diameter**

Pipe diameter of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_pipe_diameter``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `3/4" pipe`, `1" pipe`, `1-1/4" pipe`

<br/>

**Heating System 2: Type**

The type of the second heating system.
Expand Down

0 comments on commit 2e0a82a

Please sign in to comment.