e7a3381
Pull diagnostics from the switches.
dboulware Nov 29, 2023
622d153
remove old undefined variable import.
dboulware Nov 29, 2023
f931575
Update allowed sensors and states in Diagnostic metadata.
dboulware Nov 29, 2023
6b7b2a0
Initial implementation of new spu diagnositcs.
dboulware Nov 30, 2023
d8eff11
typo fix.
dboulware Nov 30, 2023
79827a3
set optional fields to None.
dboulware Nov 30, 2023
9e9007f
Update Preselector lib to 3.1.0.
dboulware Nov 30, 2023
56d0dd4
Change scos_start and scos_uptime to software_start and software_uptime.
dboulware Dec 1, 2023
b127b32
Remove requirement to have SPU-x410 switch.
dboulware Dec 1, 2023
48298e5
fix typo in power_sensors metadata.
dboulware Dec 1, 2023
0b1a42d
change diagnostics to v2.0.0
dboulware Dec 1, 2023
2364a06
Move action_runtime into computer diagnostics.
dboulware Dec 1, 2023
c947a82
move action_runtime into computer diagnostics.
dboulware Dec 1, 2023
b0231d0
Not the value of the door_closed spu sensor because 0 indicates it is…
dboulware Dec 1, 2023
3fcefb3
use door_state in switch config instead of door_closed because it is …
dboulware Dec 1, 2023
690e147
change power sensor names.
dboulware Dec 1, 2023
7f000a3
increment version.
dboulware Dec 1, 2023
1047ff6
Remove unused variables.
dboulware Dec 1, 2023
98a6fd8
run pre-commit.
dboulware Dec 1, 2023
5c4f89c
Add log warnings when expected states or sensors are not found in swi…
dboulware Dec 1, 2023
34f00f6
Corrected type of noise_diode_path_enabled and changed power sensors …
dboulware Dec 1, 2023
666ec08
Merge branch 'master' of https://github.com/NTIA/scos-actions
dboulware Dec 1, 2023
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Jump to
Jump to file
Failed to load files.
Diff view
Diff view
2 changes: 1 addition & 1 deletion pyproject.toml
Original file line number Diff line number Diff line change
Expand Up @@ -44,7 +44,7 @@ classifiers = [
dependencies = [
"environs>=9.5.0",
"django>=3.2.18,<4.0",
"its_preselector @ git+https://github.com/NTIA/Preselector@3.0.2",
"its_preselector @ git+https://github.com/NTIA/Preselector@3.1.0",
"msgspec>=0.16.0,<1.0.0",
"numexpr>=2.8.3",
"numpy>=1.22.0",
Expand Down
2 changes: 1 addition & 1 deletion scos_actions/__init__.py
Original file line number Diff line number Diff line change
@@ -1 +1 @@
__version__ = "6.4.2"
__version__ = "7.0.0"
220 changes: 167 additions & 53 deletions scos_actions/actions/acquire_sea_data_product.py
Original file line number Diff line number Diff line change
Expand Up @@ -20,6 +20,7 @@

Currently in development.
"""
import json
import logging
import lzma
import platform
Expand Down Expand Up @@ -122,20 +123,6 @@
FFT_DETECTOR = create_statistical_detector("FftMeanMaxDetector", ["mean", "max"])
PFP_M3_DETECTOR = create_statistical_detector("PfpM3Detector", ["min", "max", "mean"])

# Expected webswitch configuration:
PRESELECTOR_SENSORS = {
"temp": 1, # Internal temperature, deg C
"noise_diode_temp": 2, # Noise diode temperature, deg C
"lna_temp": 3, # LNA temperature, deg C
"humidity": 4, # Internal humidity, percentage
}
PRESELECTOR_DIGITAL_INPUTS = {"door_closed": 1}
SPU_SENSORS = {
"pwr_box_temp": 1, # Power tray temperature, deg C
"rf_box_temp": 2, # RF tray temperature, deg C
"pwr_box_humidity": 3, # Power tray humidity, percentage
}


@ray.remote
class PowerSpectralDensity:
Expand Down Expand Up @@ -704,47 +691,33 @@ def capture_diagnostics(self, action_start_tic: float, cpu_speeds: list) -> None
consecutive points as the action has been running.
"""
tic = perf_counter()
# Read SPU sensors
switch_diag = {}
all_switch_status = {}
# Add status for any switch
for switch in switches.values():
if switch.name == "SPU X410":
spu_diag = switch.get_status()
del spu_diag["name"]
del spu_diag["healthy"]
for sensor in SPU_SENSORS:
try:
value = switch.get_sensor_value(SPU_SENSORS[sensor])
spu_diag[sensor] = value
except:
logger.warning(f"Unable to read {sensor} from SPU x410")
try:
spu_diag["sigan_internal_temp"] = self.sigan.temperature
except:
logger.warning("Unable to read internal sigan temperature")
# Rename key for use with **
spu_diag["aux_28v_powered"] = spu_diag.pop("28v_aux_powered")
switch_status = switch.get_status()
del switch_status["name"]
del switch_status["healthy"]
all_switch_status.update(switch_status)

self.set_ups_states(all_switch_status, switch_diag)
self.add_temperature_and_humidity_sensors(all_switch_status, switch_diag)
self.add_power_sensors(all_switch_status, switch_diag)
self.add_power_states(all_switch_status, switch_diag)
if "door_state" in all_switch_status:
switch_diag["door_closed"] = not bool(all_switch_status["door_state"])

# Read preselector sensors
ps_diag = {}
for sensor in PRESELECTOR_SENSORS:
try:
value = preselector.get_sensor_value(PRESELECTOR_SENSORS[sensor])
ps_diag[sensor] = value
except:
logger.warning(f"Unable to read {sensor} from preselector")
for inpt in PRESELECTOR_DIGITAL_INPUTS:
try:
value = preselector.get_digital_input_value(
PRESELECTOR_DIGITAL_INPUTS[inpt]
)
ps_diag[inpt] = value
except:
logger.warning(f"Unable to read {inpt} from preselector")
ps_diag = preselector.get_status()
del ps_diag["name"]
del ps_diag["healthy"]

# Read computer performance metrics
cpu_diag = { # Start with CPU min/max/mean speeds
"cpu_max_clock": round(max(cpu_speeds), 1),
"cpu_min_clock": round(min(cpu_speeds), 1),
"cpu_mean_clock": round(np.mean(cpu_speeds), 1),
"action_runtime": round(perf_counter() - action_start_tic, 2),
}
try: # Computer uptime (days)
cpu_diag["cpu_uptime"] = round(get_cpu_uptime_seconds() / (60 * 60 * 24), 2)
Expand Down Expand Up @@ -775,13 +748,13 @@ def capture_diagnostics(self, action_start_tic: float, cpu_speeds: list) -> None
except:
logger.warning("Failed to get CPU overheating status")
try: # SCOS start time
cpu_diag["scos_start"] = convert_datetime_to_millisecond_iso_format(
cpu_diag["software_start"] = convert_datetime_to_millisecond_iso_format(
start_time
)
except:
logger.warning("Failed to get SCOS start time")
try: # SCOS uptime
cpu_diag["scos_uptime"] = get_days_up()
cpu_diag["software_uptime"] = get_days_up()
except:
logger.warning("Failed to get SCOS uptime")
try: # SSD SMART data
Expand All @@ -807,15 +780,159 @@ def capture_diagnostics(self, action_start_tic: float, cpu_speeds: list) -> None
diagnostics = {
"datetime": utils.get_datetime_str_now(),
"preselector": ntia_diagnostics.Preselector(**ps_diag),
"spu": ntia_diagnostics.SPU(**spu_diag),
"spu": ntia_diagnostics.SPU(**switch_diag),
"computer": ntia_diagnostics.Computer(**cpu_diag),
"software": ntia_diagnostics.Software(**software_diag),
"action_runtime": round(perf_counter() - action_start_tic, 2),
}

# Add diagnostics to SigMF global object
self.sigmf_builder.set_diagnostics(ntia_diagnostics.Diagnostics(**diagnostics))

def set_ups_states(self, all_switch_status: dict, switch_diag: dict):
if "ups_power_state" in all_switch_status:
switch_diag["battery_backup"] = not all_switch_status["ups_power_state"]
else:
logger.warning("No ups_power_state found in switch status.")

if "ups_battery_level" in all_switch_status:
switch_diag["low_battery"] = not all_switch_status["ups_battery_level"]
else:
logger.warning("No ups_battery_level found in switch status.")

if "ups_state" in all_switch_status:
switch_diag["ups_healthy"] = not all_switch_status["ups_state"]
else:
logger.warning("No ups_state found in switch status.")

if "ups_battery_state" in all_switch_status:
switch_diag["replace_battery"] = not all_switch_status["ups_battery_state"]
else:
logger.warning("No ups_battery_state found in switch status")

def add_temperature_and_humidity_sensors(
self, all_switch_status: dict, switch_diag: dict
):
switch_diag["temperature_sensors"] = []
if "internal_temp" in all_switch_status:
switch_diag["temperature_sensors"].append(
{"name": "internal_temp", "value": all_switch_status["internal_temp"]}
)
else:
logger.warning("No internal_temp found in switch status.")
try:
switch_diag["temperature_sensors"].append(
{"name": "sigan_internal_temp", "value": self.sigan.temperature}
)
except:
logger.warning("Unable to read internal sigan temperature")

if "tec_intake_temp" in all_switch_status:
switch_diag["temperature_sensors"].append(
{
"name": "tec_intake_temp",
"value": all_switch_status["tec_intake_temp"],
}
)
else:
logger.warning("No tec_intake_temp found in switch status.")

if "tec_exhaust_temp" in all_switch_status:
switch_diag["temperature_sensors"].append(
{
"name": "tec_exhaust_temp",
"value": all_switch_status["tec_exhaust_temp"],
}
)
else:
logger.warning("No tec_exhaust_temp found in switch status.")

if "internal_humidity" in all_switch_status:
switch_diag["humidity_sensors"] = [
{
"name": "internal_humidity",
"value": all_switch_status["internal_humidity"],
}
]
else:
logger.warning("No internal_humidity found in switch status.")

def add_power_sensors(self, all_switch_status: dict, switch_diag: dict):
switch_diag["power_sensors"] = []
if "power_monitor5V" in all_switch_status:
switch_diag["power_sensors"].append(
{
"name": "5V Monitor",
"value": all_switch_status["power_monitor5V"],
"expected_value": 5.0,
}
)
else:
logger.warning("No power_monitor5V found in switch status")

if "power_monitor15V" in all_switch_status:
switch_diag["power_sensors"].append(
{
"name": "15V Monitor",
"value": all_switch_status["power_monitor15V"],
"expected_value": 15.0,
}
)
else:
logger.warning("No power_monitor15V found in switch status.")

if "power_monitor24V" in all_switch_status:
switch_diag["power_sensors"].append(
{
"name": "24V Monitor",
"value": all_switch_status["power_monitor24V"],
"expected_value": 24.0,
}
)
else:
logger.warning("No power_monitor24V found in switch status")

if "power_monitor28V" in all_switch_status:
switch_diag["power_sensors"].append(
{
"name": "28V Monitor",
"value": all_switch_status["power_monitor28V"],
"expected_value": 28.0,
}
)
else:
logger.warning("No power_monitor28V found in switch status")

def add_heating_cooling(self, all_switch_status: dict, switch_diag: dict):
if "heating" in all_switch_status:
switch_diag["heating"] = all_switch_status["heating"]
else:
logger.warning("No heating found in switch status.")

if "cooling" in all_switch_status:
switch_diag["cooling"] = all_switch_status["cooling"]
else:
logger.warning("No cooling found in switch status")

def add_power_states(self, all_switch_status: dict, switch_diag: dict):
if "sigan_powered" in all_switch_status:
switch_diag["sigan_powered"] = all_switch_status["sigan_powered"]
else:
logger.warning("No sigan_powered found in switch status.")

if "temperature_control_powered" in all_switch_status:
switch_diag["temperature_control_powered"] = all_switch_status[
"temperature_control_powered"
]
else:
logger.warning("No temperature_control_powered found in switch status.")

if "preselector_powered" in all_switch_status:
switch_diag["preselector_powered"] = all_switch_status[
"preselector_powered"
]
else:
logger.warning("No preselector_powered found in switch status.")

def create_global_sensor_metadata(self):
# Add (minimal) ntia-sensor metadata to the sigmf_builder:
# sensor ID, serial numbers for preselector, sigan, and computer
Expand All @@ -836,9 +953,6 @@ def test_required_components(self):
msg = "Acquisition failed: signal analyzer is not available"
trigger_api_restart.send(sender=self.__class__)
raise RuntimeError(msg)
if "SPU X410" not in [s.name for s in switches.values()]:
msg = "Configuration error: no switch configured with name 'SPU X410'"
raise RuntimeError(msg)
if not self.sigan.healthy():
trigger_api_restart.send(sender=self.__class__)
return None
Expand Down
2 changes: 1 addition & 1 deletion scos_actions/metadata/sigmf_builder.py
Original file line number Diff line number Diff line change
Expand Up @@ -27,7 +27,7 @@
},
{
"name": "ntia-diagnostics",
"version": "1.1.2",
"version": "2.0.0",
"optional": True,
},
{