[libbladeRF] Loading calibration tables does not set LMS DC cal registers #336

Closed
jynik opened this issue Oct 30, 2014 · 1 comment
Closed
Assignees
Labels
Issue: Bug It's a bug and it oughta be fixed
Milestone

Comments

@jynik
Copy link
Contributor

jynik commented Oct 30, 2014

It appears that although cal data is loaded, the stored LMS DC offset registers are not being written to the device.

This is apparent when opening a device (with an FPGA and cal tables being autoloaded, for example), and running cal lms show -- all the results will come back as "undefined" values of 31.

@jynik jynik added the Issue: Bug It's a bug and it oughta be fixed label Oct 30, 2014
@jynik jynik self-assigned this Oct 30, 2014
@jynik jynik added this to the 2014.09-rc3 milestone Oct 30, 2014
@jynik
Copy link
Contributor Author

jynik commented Oct 30, 2014

Fixed in 2cb315d.