[SEWater] 10313 Gas Reading and RR 6041 #167
Conversation
This PR supersedes PR #149
@aforster23 We discussed today and need clarification on the RR 6041 range enumeration. Please clarify what 0 means and what 400 e.g. means in the description field. Is the value a counter or a static value or a value that can be set? If the value is a counter, does it run down to zero when ready? |
Hi, the reusable resource used for 6041 is the "Sample Warm Up time". The XML I submitted shows the range enumeration from 0 to 86400 seconds. The Description listed is: "Warm-up (wait) time before sensor value is read". If this is unclear, then in other words the Sample time is how long a device waits before it takes a reading from the gas sensor (which is attached or integrated to said IoT device). It is a RW value that can be changed via the server at any time. It will usually be set to a given default (depending on the warm-up time required for the different gas sensors), but is fully configurable if required. Please let me know if you need more information. The XML of this resource is as below: - |
@aforster23 Is it possible to create a special meeting to discuss and collaborate with the IPSO Working Group in the near future. We still have questions about how the RR is used. Specifically what is the warm up time is based upon? What happens if the sensor is read but isn't warmed up, etc. We would like to clarify the description and name the resource appropriately. Thanks! Matt |
Hi Matt, happy to catch up about this. Most sensors (especially those measuring gas or other volatile parameters) need to be powered on for a small duration so that they "warm up " in order to then get a stable reading. Without the warm up time,the initial readings from the sensor would be wildly fluctuating. The warm up time let's the sensor reach some equilibrium to give a more stable reading.
Thanks
…Sent from my iPhone
On 21 Jun 2019, at 2:03 am, mkgillmore <notifications@github.com<mailto:notifications@github.com>> wrote:
@aforster23<https://github.com/aforster23> Is it possible to create a special meeting to discuss and collaborate with the IPSO Working Group in the near future. We still have questions about how the RR is used. Specifically what is the warm up time is based upon? What happens if the sensor is read but isn't warmed up, etc. We would like to clarify the description and rename the resource appropriately. Thanks! Matt
-
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub<#167?email_source=notifications&email_token=AI2624UX4EYQJW6O6LAYTMTP3OS2FA5CNFSM4HXQTK32YY3PNVWWK3TUL52HS4DFVREXG43VMVBW63LNMVXHJKTDN5WW2ZLOORPWSZGODYF3TRQ#issuecomment-504084934>, or mute the thread<https://github.com/notifications/unsubscribe-auth/AI2624QZECF4RSDUZOOV3R3P3OS2FANCNFSM4HXQTK3Q>.
________________________________
**********************************************************************
Information contained in this e-mail, including accompanying
documents, is intended for use of the addressee only. If
you are not the intended recipient, please notify the sender
as soon as possible and delete the e-mail. If you are not
the intended recipient, you may not distribute, copy, act
upon, retain or otherwise use this e-mail or information
contained here. The confidential and possibly privileged
nature of the information contained in this e-mail is not
waived by reason of mistaken delivery to other than the
intended recipient. Your use or reproduction of this e-mail
and accompanying documents may also breach South
East Water's copyright.
**********************************************************************
South East Water
ABN 89 066 902 547
101 Wells Street, Frankston
VIC 3199 Australia
Phone: (+61 3) 9552 3000 Fax: (+61 3) 9552 3001
Web: http://www.southeastwater.com.au
|
This PR replaces PR #149. This PR has a conflict and it cannot be resolved easily.
The new PR reproduces the latest changes on PR #149