Notifications
You must be signed in to change notification settings - Fork 916
/
eur_spiritz.xml
110 lines (107 loc) · 5.39 KB
/
eur_spiritz.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
<?xml version="1.0" encoding="utf-8"?>
<!--
Eurotronic Spirit Z-Wave Plus Thermostat
Product website: https://www.eurotronic.org/produkte/spirit-z-wave-plus.html
Tech manual: https://www.eurotronic.org/fileadmin/user_upload/eurotronic.org/Produktbilder/spirit_z_wave_plus/Spirit_Z-Wave_BAL_web_EN_view_04.pdf
-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Multilevel switch for setting valve opening -->
<CommandClass id="38">
<Value type="byte" genre="user" index="0" label="Valve Opening" units="%" min="0" max="100" value="0" />
</CommandClass>
<!-- Thermostat mode -->
<CommandClass id="64">
<Instance index="1" />
<Value type="list" genre="user" instance="1" index="0" label="Mode">
<Help>
Off: No heating, only frost protection.
Auto: Room temperature will be kept at the configured setpoint.
Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy.
Full Power: Full power heating. This mode is left automatically after 5 minutes.
Manufacturer Specific: Direct valve control mode. The valve opening percentage can be controlled using the switch multilevel command class.
</Help>
<Item label="Off" value="0" />
<Item label="Auto" value="1" />
<Item label="Eco" value="11" />
<Item label="Full Power" value="15" />
<Item label="Manufacturer Specific" value="31" />
</Value>
<SupportedModes>
<Mode index="0" label="Off" />
<Mode index="1" label="Auto" />
<Mode index="11" label="Eco" />
<Mode index="15" label="Full Power" />
<Mode index="31" label="Manufacturer Specific" />
</SupportedModes>
</CommandClass>
<!-- Setpoints -->
<CommandClass id="67" base="0" typeInterpretation="A">
<Instance index="1"/>
<Value type="decimal" genre="user" instance="1" index="1" label="Target Temperature" units="°C" read_only="false" write_only="false" min="8" max="28" value="20"/>
<Value type="decimal" genre="user" instance="1" index="11" label="Target Temperature Eco" units="°C" read_only="false" write_only="false" min="8" max="28" value="16"/>
</CommandClass>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Instance index="1"/>
<Value type="list" genre="config" instance="1" index="1" label="LCD Invert" min="0" max="1" value="0" size="1">
<Help>
Allows rotating the LCD contents by 180 degrees.
Default: Normal
</Help>
<Item label="Normal" value="0" />
<Item label="Upside Down" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="LCD Timeout" min="0" max="30" units="sec" value="0">
<Help>
0: No Timeout, LCD always on.
5-30: Timeout after 5-30s.
Default: 0 (LCD always on)
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="3" label="Backlight" min="0" max="1" units="" value="1" size="1">
<Help>
Default: Backlight enabled
</Help>
<Item label="Backlight disabled" value="0" />
<Item label="Backlight enabled" value="1" />
</Value>
<Value type="list" genre="config" instance="1" index="4" label="Battery Report" min="0" max="1" units="" value="1" size="1">
<Help>
Default: Send once a day
</Help>
<Item label="Only send battery status as notification" value="0" />
<Item label="Send once a day" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="5" label="Temperature Report Threshold" min="0" max="50" units="0.1°C" value="5">
<Help>
0: Don't send temperature automatically.
1-50: Report temperature at 0.1-5.0°C temperature difference.
Default: 5 (Delta = 0.5°C)
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="6" label="Valve Opening Percentage Report" min="0" max="100" units="" value="0">
<Help>
0: Don't send Valve opening percentage automatically.
1-100: Report valve opening percentage at a delta of 1-100%.
Default: 0
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="7" label="Open Window Detection" min="0" max="3" units="" value="2" size="1">
<Help>
Default: Medium sensibility
</Help>
<Item label="Disabled" value="0" />
<Item label="Low sensibility" value="1" />
<Item label="Medium sensibility" value="2" />
<Item label="High sensibility" value="3" />
</Value>
<Value type="byte" genre="config" instance="1" index="8" label="Measured Temperature Offset" min="0" max="255" units="" value="0">
<Help>
206-255: -5.0 to -0.1°C.
0-50: 0°C-5°C.
128: External Temperature Sensor.
Default: 0 (0.0°C Offset)
</Help>
</Value>
</CommandClass>
</Product>