<?xml version="1.0" encoding="utf-8"?>
<!--
Aeotec ZW089 Recessed Door Sensor Gen5
https://aeotec.freshdesk.com/helpdesk/attachments/6009584697
-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration -->
<!-- Alarm CC isn't supported on this device -->
<CommandClass id="113" action="remove"/>
<CommandClass id="112">
<Value type="list" genre="config" instance="1" index="1" label="Sensor Binary Report Toggle" min="0" max="1" value="0">
<Help>Which value of the Sensor Binary Report will be sent when
the magnet switch to open/close.</Help>
<Item label="Normal" value="0"/>
<Item label="Inverse" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="3" label="Basic Set Toggle" min="0" max="1" value="0">
<Help>Which value of the Basic Set will be sent when the magnet
switch to open/close.
</Help>
<Item label="Normal" value="0"/>
<Item label="Inverse" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="101" label="Low Battery Check Enable" min="0" max="1" value="0">
<Help>Enable/disable the function of low battery checking, when
the current voltage is less than the warning voltage, it will
send the Battery Low Warning Report.
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="int" genre="config" instance="1" index="111" label="Low Battery Check Interval" min="0" max="4294967295" value="86640">
<Help>This parameter is available when the low battery checking
function is activated or the device was waked up by other
actions (i.e. the z-wave button trigger, magnet switch
trigger and the Wake Up Interval Set timeout trigger).
The Recessed Door Sensor will check the battery power
when it was wake up as other ways. For example: the
z-wave button trigger, magnet switch trigger and the
Wake Up Interval Set timeout trigger.
Default setting: 86640
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="121" label="Report Type" size="4" value="256">
<Help>Configure which sensor report will be sent when the sensor is Opened/Closed</Help>
<Item label="Disabled" value="0"/>
<Item label="Basic Set" value="256"/>
<Item label="Sensor Binary Report" value="16"/>
<Item label="Basic Set and Sensor Binary Report" value="272"/>
</Value>
<Value type="list" genre="config" index="252" label="Lock/Unlock Configuration" min="0" max="1" size="1" value="0">
<Help>Lock/ unlock all configuration parameters</Help>
<Item label="Unlock" value="0"/>
<Item label="Lock" value="1"/>
</Value>
<Value type="short" index="254" genre="config" label="Device Tag" units="" min="0" max="65535" value="0">
<Help>Device Tag</Help>
</Value>
<Value type="button" index="255" genre="config" label="Reset To Factory Defaults" write_only="true" value="0" >
<Help>Reset to factory defaults.</Help>
</Value>
</CommandClass>
<!-- Basic set as report-->
<CommandClass id="32" setasreport="true"/>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="5" label="LifeLine" />
<Group index="2" max_associations="5" label="Battery" auto="true"/>
</Associations>
</CommandClass>
</Product>