Notifications
You must be signed in to change notification settings - Fork 915
/
eur_temphumin.xml
92 lines (86 loc) · 3.92 KB
/
eur_temphumin.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
<?xml version="1.0" encoding="utf-8"?>
<!--
Eurotronic Z-Wave Plus temperature and humitity sensor
Product website: https://eurotronic.org/produkte/sensoren/temperatur-feuchte-sensor/
-->
<Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0148:0001:0004</MetaDataItem>
<MetaDataItem name="Name">Temperature and Humidity Sensor</MetaDataItem>
<MetaDataItem name="ProductPic">images/eurotronic/eur_temphumid.png</MetaDataItem>
<MetaDataItem name="InclusionDescription">Start Inclusion mode of your primary Z-Wave Controller.
Press the network button three times within 1 second.</MetaDataItem>
<MetaDataItem name="ResetDescription">Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Press and hold the network button for at least 10 seconds. The temperature humidity sensor will indicate
the reset blinking pattern once the reset is completed.
</MetaDataItem>
<MetaDataItem id="0001" name="FrequencyName" type="0004">CEPT (Europe)</MetaDataItem>
<MetaDataItem id="0001" name="ZWProductPage" type="0004">https://eurotronic.org/produkte/sensoren/temperatur-feuchte-sensor/</MetaDataItem>
<MetaDataItem name="ProductManual">https://eurotronic.org/</MetaDataItem>
<MetaDataItem name="Description">
<!--
TODO: English manual not yet available on website of eurotronics
-->
This Z-Wave sensor provides comprehensive information on indoor
temperature and humidity.
• Returns the following values:
- Temperature (°C)
- Humidity (%)
- Dew point (°C)
• Supports Z-Wave Plus S2 security (encryption)
</MetaDataItem>
<ChangeLog>
<Entry author="gpgmailencrypt@gmx.de" date="13 Mar 2020" revision="2">Initial Metadata Import </Entry>
</ChangeLog>
</MetaData>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Instance index="1"/>
<Value type="byte" genre="config" instance="1" index="1" label="Temperature on Change Reporting" min="0" max="50" value="5" size="1">
<Help>
0: Don't report temperature changes
1-50: Report temperature changes from 0,1°C - 5,0°C
Default: 5
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Humidity on Change Reporting" min="0" max="10" value="5" size="1">
<Help>
0: Don't report humidity changes
1-10: report humidity changes in 1% steps
Default: 5
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="3" label="Temperature Scale" min="0" max="1" value="0" size="1">
<Help>
0: Temperature in Degrees Celcius
1: Temperature in Degrees Fahrenheit
Default: 0
</Help>
<Item label="Celsius" value="0" />
<Item label="Fahrenheit" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="Temperature Resolution" min="0" max="2" value="1" size="1">
<Help>
0: no decimal places
1: one decimal place
2: two decimal places
Default: 1
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="5" label="Humidity Resolution" min="0" max="2" value="0" size="1">
<Help>
0: no decimal places
1: one decimal place
2: two decimal places
Default: 0
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="1" label="Lifeline" />
<Group index="2" max_associations="5" label="Temperature" />
</Associations>
</CommandClass>
</Product>