Notifications
You must be signed in to change notification settings - Fork 915
/
dsc12104.xml
153 lines (143 loc) · 6.26 KB
/
dsc12104.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
<?xml version="1.0" encoding="utf-8"?>
<!--
Aeotec DSC12104 Micro Smart Energy Switch
https://aeotec.freshdesk.com/helpdesk/attachments/6009584526
-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="short" index="2" genre="config" label="Blinking behavior" units="" min="0" max="65535" write_only="true" value="0">
<Help>
This is actually a double byte value. The LSB defines the total time the device needs to blink in seconds. The MSB defines the on/off interval of the blink in tenths of seconds.
</Help>
</Value>
<Value type="list" index="3" genre="config" label="Current Overload Protection" units="" size="1" value="0">
<Help>Current Overload Protection</Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="1" />
</Value>
<Value type="list" index="80" genre="config" label="Notification status" units="" size="1" value="0">
<Help>
Enables automatic notifications to associated devices whenever there is a state change.
</Help>
<Item label="None" value="0" />
<Item label="Hail" value="1" />
<Item label="Basic" value="2" />
</Value>
<Value type="bool" index="90" genre="config" label="Enable Wattage Reports" units="" value="0">
<Help>
Enable/disable Wattage threshold and percent.
</Help>
</Value>
<Value type="short" index="91" genre="config" label="Wattage threshold" units="watts" min="0" max="32000" value="50">
<Help>
The minimum change in wattage for a report to be sent.
</Help>
</Value>
<Value type="byte" index="92" genre="config" label="Wattage threshold percent" units="%" min="0" max="99" value="10">
<Help>
Minimum change in percent of wattage to send a report.
</Help>
</Value>
<Value type="button" index="100" genre="config" label="Default Group Reports" units="" write_only="true" value="0" affects="101,102,103">
<Help>
Set report types for groups 1, 2 and 3 to default. Reverts to 0
after set.
</Help>
</Value>
<Value type="int" index="101" genre="config" label="Report type G1" units="" value="0">
<Help>
Defines the type of report sent for reporting group 1. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC(KWH)
bit 2 MRC(watt)
bit 1 MSRC
bit 0 reserved
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
</Help>
</Value>
<Value type="int" index="102" genre="config" label="Report type G2" units="" value="0">
<Help>
Defines the type of report sent for reporting group 2. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC(KWH)
bit 2 MRC(watt)
bit 1 MSRC
bit 0 reserved
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
</Help>
</Value>
<Value type="int" index="103" genre="config" label="Report type G3" units="" value="0">
<Help>
Defines the type of report sent for reporting group 3. 2 is multisensor report. 4 is meter report for watts. 8 is meter report for kilowatts.
Value 1 (msb) Reserved
Value 2 Reserved
Value 3 Reserved
Value 4 (lsb) bits 7-4 reserved
bit 3 MRC(KWH)
bit 2 MRC(watt)
bit 1 MSRC
bit 0 reserved
The MRC(KWH) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(KWh) automatically.
The MRC(Watt) flag signals that Report Group 1 send(1) or don't send(0)
Meter Report Command(wattage) automatically.
The MSRC flag signals that Report Group 1 send(1) or don't send(0)
Multilevel Sensor Report Command(wattage) automatically.
</Help>
</Value>
<Value type="button" index="110" genre="config" label="Default Group Time" units="" write_only="true" value="0" affects="111,112,113">
<Help>
Set time interval for sending reports for groups 1, 2 and 3 to default.
</Help>
</Value>
<Value type="int" index="111" genre="config" label="Send interval G1" units="seconds" min="0" max="65535" value="600">
<Help>
Defines the time interval when the defined report for group 1 is sent.
</Help>
</Value>
<Value type="int" index="112" genre="config" label="Send interval G2" units="seconds" min="0" max="65535" value="600">
<Help>
Defines the time interval when the defined report for group 2 is sent.
</Help>
</Value>
<Value type="int" index="113" genre="config" label="Send interval G3" units="seconds" min="0" max="65535" value="600">
<Help>
Defines the time interval when the defined report for group 3 is sent.
</Help>
</Value>
<Value type="list" index="120" genre="config" label="Set External Switch/Button Control mode" units="" size="1" value="1">
<Help>Set External Switch/Button Control mode</Help>
<Item label="Momentary button" value="0" />
<Item label="2 state switch" value="1" />
</Value>
<Value type="short" index="254" genre="config" label="Device tag" units="" min="0" max="65535" value="0">
<Help>Device tag.</Help>
</Value>
<Value type="button" index="255" genre="config" label="Reset device" units="" write_only="true" value="0">
<Help>Reset to the default configuration.</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline" />
</Associations>
</CommandClass>
</Product>