<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Yale Keyfree Connected (YKFCON)
http://ozw.my-ho.st/Yale/Yale%20ZWave%20Developer%20Guide.pdf
https://products.z-wavealliance.org/products/2743/configs
-->
<!-- Yale Keyless Connected (YD-01-CON)
https://products.z-wavealliance.org/products/2576/configs
-->
<!-- Configuration -->
<CommandClass id="112">
<Value type="list" size="1" genre="config" instance="1" index="1" label="Volume Level" value="3">
<Help>Volume of the keypad tones and any voice prompts (default = 3, high)</Help>
<Item label="Silent" value="1" />
<Item label="Low" value="2" />
<Item label="High" value="3" />
</Value>
<Value type="list" size="1" genre="config" instance="1" index="2" label="Auto Relock" value="0">
<Help>Enable or disable the Auto relock feature (default = 255, enable)</Help>
<Item label="Enable" value="255" />
<Item label="Disable" value="0" />
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Relock Time" size="1" min="7" max="60" units="seconds" value="7">
<Help>After successful local unlock, automatically relock after the specified time (default = 7 seconds)</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="6" label="Remote Relock Time" size="1" min="10" max="90" units="seconds" value="10">
<Help>After successful remote unlock, automatically relock after the specified time (default = 10 seconds)</Help>
</Value>
</CommandClass>
<CommandClass id="113">
<!-- These Door Locks don't send a DoorLockReport when the
Lock Status is Changed, but instead send a Alarm Message -
So we trigger a Refresh of the DoorLock Command Class when
we recieve a Alarm Message Instead -->
<TriggerRefreshValue Genre="user" Index="0" Instance="1">
<RefreshClassValue CommandClass="98" RequestFlags="0" Index="1" Instance="1" />
</TriggerRefreshValue>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline"/>
</Associations>
</CommandClass>
</Product>